Specification
Property
Maximum flow rate
Maximum suction
Maximum head
Maximum horizontal run
Sound
Voltage
Power
Alarm relay
Operation temperature
Water temperature
Ingress protection
Packaging dimensions
Weight
Compliance
Spare Parts and Accessories
3004063
3004065
3004087
3004186
4679160
4678597
3004187
3004113
4687950
3004180
3004166
3004139
Value
42 l / h (11 GPH)
3 m (9.80 ft.) self priming
20 m (65.60 ft.)
100 m (330 ft.) at 0 head and 0
suction
20 dB(A) at 1 m DIN EN ISO
3741:2011 / DIN EN ISO 3744:2010
100 - 240 VAC 50/60 Hz
8 W during maximum operation
at 120 V
7 Amp contacts with integrated
replaceable 6.3 A fuse 5 × 20 mm
5 °C to 40 °C (41 °F to 104 °F)
5 °C to 40 °C (41 °F to 104 °F)
IP44
250 × 340 × 54 mm (9.9 × 13.4 × 2.1 inches)
1.000 g (2.2 lb.)
CE, Conforms to UL 778, CSA
C22.2 #108 and UL 2043
FIL-4063/4 (Spare filter)
HSG-4065/4 (Siphon device)
KIT-4087 (Star tube & siphon)
STAR-TUBE-600 (15 m)
PVC-TUBE (1/4" / 6 mm, 30 m)
IN-LINE-FILTER
COMBI-SHIELD (Sensor protection)
COMBI-SEN (Spare sensor)
COMBI-SEN-CABLE (Water sensor cable)
FUS-4180/10 (Spare fuses)
CP-ALARM-CABLE (Alarm cable)