Εισαγωγέας: Inventronics Netherlands B.V., Polluxstraat 21, 5047RA Tillburg
Forgalmazó: Inventronics Netherlands B.V., Polluxstraat 21, 5047RA Tillburg
Inventronics Poland Sp. z o.o., Al. Jerozolimskie 94, 00-807 Warsaw, Poland
Inventronics Turkey Teknoloji Ticaret Limited Şirketi, Buyukdere Cad. Bahar Sok. River Plaza No: 13/5 Sisli 34394 Istanbul, Turkey
Uvoznik: Inventronics Netherlands B.V., Polluxstraat 21, 5047RA Tillburg
Inventronics Netherlands B.V., Polluxstraat 21, 5047RA Tillburg
Инвентроникс Нидерландия Б.В., Полукстраат 21, 5047 РА Тилбург
Inventronics Guangzhou Technology Limited; Room 1105, Clifford Corporate Center Building, No. 15, Fuhua Road, Clifford Estate Panyu, Guangzhou,
Guangdong province, China, Postal code: 511496
广州英飞特科技有限公司; 广州市番禺区钟村街祈福新邨福华路15号祈福集团中心1105室 邮编: 511496
INVENTRONICS MALAYSIA SDN. BHD., Kuala Lumpur, Penang, Tower A Vertical Business Suite
Inventronics Korea Inc, Seoul, Yeongdong-daero 417
인벤트로닉스코리아 유한회사, 서울특별시 강남구 테헤란로25길 6-9, 6층 674호
INVENTRONICS (HONG KONG) LIMITED, Room 30-108C, 29/F, Tower 5, The Gateway, 15 Canton Road, Tsim Sha Tsui, Hong Kong
INVENTRONICS SSL India Private Limited, 4th and 5th floor, B Wing, Valipeer Road, Kalyan West, Kalyan, Thane, Maharashtra-421301
WARNING: DALI (FELV) control terminals are not safe to touch. Circuits connected to any DALI (FELV) control terminal shall be
insulated for the LV supply voltage of the control gear, and any terminals connected to the DALI (FELV) circuit shall be protected
against accidental contact. OTi DALI 15 NFC LP I classified as "Do not cover" (see symbol on the right): The independent LED driver
can be used where normally flammable materials, including building insulation, are or may be present, but cannot be abutted against
any material and cannot be covered in normal use. OTi DALI 25 NFC LP I and OTi DALI 40 NFC LP I classified as "Non IC": The
independent LED driver cannot be abutted against or covered by normally flammable materials or used in installations where building
insulation or debris is, or may be, present in normal use. No use for residential installations. The minimum clearance distance from
the top and sides of the independent LED driver to normally flammable building elements is A=B=C=10mm.
Barrier required for loose fill insulation
or loose combustible materials
A
C
C10449058
G15130208
10.02.25
Combustible building element above fitting
Combustible building
B
structural member