Preparing furniture doors

Note:
When working on furniture doors, always observe
the following:
Select a furniture door thickness between at least
5/8" (16 mm) and 3/4" (19 mm).
Always select a screw length which is shorter
than the thickness of the furniture door.
Always insert screws into the part of the furniture
door which is best able to handle the load.
Do not insert screws into fillings, or similar.
Do not insert screws into filters, decorative strips,
or similar.
Protect the furniture door surfaces against
damage during installation.

Furniture door dimensions

Key
A
Furniture door protrusion
B
Lower edge of furniture door
The specified furniture door dimensions apply for a
door gap of
/
" (4 mm).
5
32

Connecting the appliance

After installing the appliance, wait at least 8 hours
until the appliance is switched on. During
transportation the oil in the compressor may have
flowed into the refrigeration system.
Before switching on the appliance for the first time,
clean the interior of the appliance (see chapter
Cleaning the appliance).

Electrical connection

9
WARNING:
Avoid the risk of an electric shock!
9
WARNING:
Insert into a grounded 3-phase socket. Never remove
grounding phase. Do not use any adapters. Do not use
any extension cables.
9
WARNING:
Non-compliance with these instructions may result
in death, fire or an electric shock. Improper
connection of the protective conductor may result in
an electric shock. If you are in doubt whether
the appliance has been grounded properly, have
the appliance tested by a qualified electrician or
service technician.
Do not use extension cables or distributors. This
appliance must be connected to a permanently
installed socket.
The socket must be near the appliance and also freely
accessible following installation of the appliance.
The appliance complies with protection class I.
Connect the appliance to 115 V/60 Hz alternating
current via a correctly installed socket with protective
conductor. The socket must be fused with a 10 to 16 A
fuse.
The appliance comes with a UL registered 3-wire
power cord. The appliance requires a 3-pole socket.
Please observe the following table with regard to this:
Appliance
Maximum simulta-
neous load
Fridge-
6.0 amps
freezer
Check on the rating plate whether the indicated
voltage and current type correspond with the values of
your power supply. The location of the rating plate
can be found in the chapter entitled Customer
service.
9
WARNING:
Never connect the appliance to electronic energy
saver plugs.
Our appliances can be used with mains and sine-
controlled inverters. Mains-controlled inverters
are used for photovoltaic systems which
are connected directly to the national grid. Sine-
controlled inverters must be used for isolated
applications (e.g. on ships or in mountain lodges)
which are not connected directly to the national grid.