The figure below shows the clearance from surfaces
Lateral view
Top view
Notice:
Heosbox cannot be installed in enclosed spaces where no natural ventilation
(1)
can be ensured, otherwise there will be a decline in performance and the unit
will probably malfunction. Furthermore, adequate clearance must be provided
in all directions, except for underneath the support base, so as to ensure correct
operation of the unit.
The unit's packaging is made with wooden pallets and a cardboard box fixed
(2)
with plastic straps. The packages can be stacked one on top of the other, up to
a maximum of three, as long as the unit is kept in the correct position (see the
symbols printed on the packaging). Note, there is residual risk of the load falling
from the transport vehicle, if these limits are exceeded
(3)
Clearance in other directions not shown in the figure: 300 mm (11.81 in).
Heos BOX - NAM version +0300097EF - rel. 1.0 - 17.06.2021
.
(3)
wall
wall
Fig. 2.d
wall
wall
Fig. 2.e
.

2.9 Refrigeration unit components

The following table describes the individual components making up the
unit.
Ref.
Position
Description
1
Fig.2.g
Unit fixing tabs
2
Fig.2.g
Unit lifting corners
3
Fig.2.h
Electric panel ventilation air intake grille
4
Fig.2.h
Electric panel ventilation air exhaust grille
12
Fig.2.h
Wi-Fi gateway kit cable gland
13
Fig.2.h
RJ485 port for controller display
14
Fig.2.h
Electrical panel main switch
15
Fig.2.f & 2.g
Discharge temperature probe
16
Fig.2.f & 2.g
Compressor
17
Fig.2.f & 2.g
Suction pressure transducer
18
Fig.2.f & 2.g
Liquid receiver
19
Fig.2.f & 2.g
Filter-drier
20
Fig.2.f & 2.g
Liquid temperature probe
21
Fig.2.f & 2.g
Water inlet temperature probe
22
Fig.2.f & 2.g
Condenser
23
Fig.2.f & 2.g
Water inlet connection
24
Fig.2.f & 2.g
Liquid injection valve
25
Fig.2.f & 2.g
Discharge pressure transducer
27
Fig.2.f & 2.g
Safety pressure switch
28
Fig.2.f & 2.g
Water outlet temperature probe
29
Fig.2.g
Suction temperature probe
(1)
30
Fig.2.f & 2.g
Check valve
31
Fig.2.f & 2.g
Refrigerant inlet shut-off valve
32
Fig.2.f & 2.g
Refrigerant outlet shut-off valve
33
Fig.2.f & 2.g
Liquid/moisture indicator
34
Fig.2.f & 2.g
Refrigerant inlet connection
35
Fig.2.f & 2.g
Refrigerant outlet connection
36
Fig.2.f & 2.g
Water outlet connection
37
Fig.2.f & 2.g
Oil separator
(2)
38
Fig.2.f & 2.g
Capillary tube
(2)
39
Fig.2.f & 2.g
Discharge pressure port
40
Fig.2.f & 2.g
Suction pressure port
43
Fig.2.f & 2.g
Sensor terminals
45
Fig.2.h
Wi-Fi gateway terminals
46
Fig.2.h
Inverter
47
Fig.2.h
Free cable gland
48
Fig.2.f & 2.g
Liquid line pressure port
49
Fig.2.f & 2.g
Safety valve
(3)
50
Fig.2.g
Serial connectors
(3)
52
Fig.2.h
Transformer
(3)
53
Fig.2.h
Electrical protections
(4)
54
Fig.h
Heos controller
Notice:
available only on single evaporator units
(1)
available only on multi-evaporator units
(2)
(3)
for NAM versions only
NAM versions as standard use circuit breakers.
(4)
12
Tab. 2.k

Publicité

Chapitres

Table des Matières
loading

Table des Matières