2.4 Technical specifications

Technical specifications for NAM versions
Family
Type: MT/LT Single Evaporator
Type: MT Multi-Evaporator
Standard configuration
Power supply
Compressor current draw - R448A - R449A
Max unit current draw - R448A - R449A (1)
MCA (4) R448A - R449A
MOP (5) R448A - R449A
MinOP (6) R448A - R449A
Cooling capacity with R448A - R449A (2)
Sound power
Condenser water flow-rate (3)
Condenser pressure drop (3)
Refrigerant side - Max allowable pressure - HP
Refrigerant side - Max allowable pressure - LP
Refrigerant side - Max allowable temperature
Safety valve opening pressure
Pressure switch opening pressure (7)
Water side - Max operating pressure
Water side - Max operating temperature
MT/LT Single Evaporator unit and LT Multi Evaporator unit, NAM version – Low Temperature operation
Family
Type: MT/LT Single Evaporator
Type: LT Multi Evaporator
Standard configuration
Power supply
Compressor current draw - R448A - R449A
Max unit current draw - R448A - R449A (1)
MCA (4) R448A - R449A
MOP (5) R448A - R449A
MinOP (6) R448A - R449A
Cooling capacity with R448A - R449A (2)
Sound power
Condenser water flow-rate (3)
Condenser pressure drop (3)
Refrigerant side - Max allowable pressure - HP
Refrigerant side - Max allowable pressure - LP
Refrigerant side - Max allowable temperature
Safety valve opening pressure
Pressure switch opening pressure (7)
Water side - Max operating pressure
Water side - Max operating temperature
Notice:
(1)
When calculating the maximum current draw, it is assumed that the defrost
heaters and compressor never operate simultaneously as expected by the con-
struction of the electrical panel. Therefore, this value includes the Heos high ef-
ficiency showcase controller and all of the control signals of the auxiliary loads
(see paragraph 2.7). Pay special care with the multi-evaporator configuration (see
page 7)
The nominal conditions refer to AHRI Standard 540:
(2)
• MT Tevap=-6.5°C (20.3°F)
• Tcond=43.5°C (110.3°F)
• LT Tevap=-31.5°C (-24.7°F)
• Tcond=40.5°C (104.9°F)
• superheat=10K
Heos BOX - NAM version +0300097EF - rel. 1.0 - 17.06.2021
MT/LT Single Evaporator and MT Multi-Evaporator, NAM version - Medium Temperature operation
V
Ph
Hz
[A]
[A]
[A]
[A]
[A]
[kW]
[dB(A)]
[l/min] / [US gpm] 11.5/3.04
[kPa] / [psi]
[Bar] / [psi]
[bar] / [psi]
[°C] / [°F]
[Bar] / [psi]
[Bar] / [psi]
[bar] / [psi]
[°C] / [°F]
V
Ph
Hz
[A]
[A]
[A]
[A]
[kW]
[dB(A)]
[l/min] / [US gpm] 8.06/2.13
[kPa] / [psi]
[bar] / [psi]
[bar] / [psi]
[°C] / [°F]
[Bar] / [psi]
[Bar] / [psi]
[bar] / [psi]
[°C] / [°F]
HB1US
03M
04M
03E
04E
0W1A0
0W1A0
200-220
200-220
2+N
2+N
50-60Hz
50-60Hz
5.2
7.4
7.2
9.4
10.8
11.8
15
15
15
15
1.9
2.7
<65
<65
17.8/4.7
28.4/4.12
30.8/4.47
40/580
40/580
22/319
22/319
100/212
100/212
40/580
40/580
35/508
35/508
15.9/231
15.9/231
48/118.4
48/118.4
HB1US
03M
04M
L0D
L1D
0W1A0
0W1A0
200-220
200-220
2+N
2+N
50-60Hz
50-60Hz
5.2
7.4
7.2
9.4
10.8
11.8
15
15
15
15
0.5
0.7
<65
<65
8.4/2.12
28.4/4.12
28/4.06
40/580
40/580
22/319
22/319
100/212
100/212
40/580
40/580
35/508
35/508
15.9/231
15.9/231
48/118.4
48/118.4
(3)
LT Tevap=-35°C (-31°F)
Tcond=40°C (104°F);
superheat = 10K,
subcooling = 0K.
The data refer to a water flow rate containing 20% antifreeze (ethylene glycol)
additive by volume. By varying the percentage by volume of antifreeze additive
(ethylene glycol) in the water circuit, the reported performance and pressure
drop will vary from the values shown in the tables.
(4)
Minimum circuit current for sizing the cables.
Maximum current for overcurrent protection.
(5)
Minimum current for overcurrent protection.
(6)
(7)
Manual reset of the pressure switch at 29bar / 421psi.
10
06M
08M
06E
08E
0W1A0
0W1B0
200-220
200-220
2+N
2+N
50-60Hz
50-60Hz
12.6
16.5
14.6
18.5
18.2
23.4
25
45
20
30
4.1
6.1
<65
<65
24.4/6.45
46.9/12.39
30.5/4.42
27.9/4.05
40/580
40/580
22/319
22/319
100/212
100/212
40/580
40/580
35/508
35/508
15.9/231
15.9/231
48/118.4
48/118.4
06M
08M
02D
03D
0W1A0
0W1B0
200-220
200-220
2+N
2+N
50-60Hz
50-60Hz
12.6
16.5
14.6
18.5
18.2
23.4
25
45
20
30
1.1
1.6
<65
<65
11.5/3.04
17.8/4.70
28.5/4.13
30.7/4.45
40/580
40/580
22/319
22/319
100/212
100/212
40/580
40/580
35/508
35/508
15.9/231
15.9/231
48/118.4
48/118.4
08M
08E
3W1B0
200-220
2+N
50-60Hz
21.1
23.1
27.5
45
30
7.9
<65
47/12.42
28.1/4.07
40/580
22/319
100/212
40/580
35/508
15.9/231
48/118.4
Tab. 2.e
08M
02D
3W1B0
200-220
2+N
50-60Hz
21.1
23.1
27.5
45
30
2.0
<65
24.5/6.47
30.7/4.45
40/580
22/319
100/212
40/580
35/508
15.9/231
48/118.4
Tab. 2.f