Dometic Kampa CARAVAN AIR AWNINGS Guide D'utilisation page 12

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 19
The AirPoles do not need any maintenance but should be protected from damage during storage. Have any damage
repaired at the first opportunity.
Zips should be treated with care, use two hands to close and open and never tread on them. Never force a zip.
We strongly recommend that you carry a comprehensive spares kit including Kampa Dometic waterproof spray,
Kampa Dometic seam sealer and Kampa Dometic repair tape.
Repairs should only be made by a company authorised by Kampa Dometic or your supplying dealer. Repairs and
alterations made by an unauthorised company may invalidate your guarantee.
Guarantee
Kampa Dometic AIR awnings are covered by a comprehensive guarantee and we offer an excellent aftersales service
that can be accessed through your supplying dealer.
AirFrame - 2 years / Other components - 1 year
The guarantee covers manufacturing faults, materials and parts. The guarantee does not cover fading and UV
degradation, misuse, accidental damage, storm damage, permanent, semi-permanent* or commercial use. It does not
cover consequential losses.
Please contact your supplying dealer to make a claim. This does not affect your statutory rights.
* All-Season models have been designed for use on seasonal pitches.
Troubleshooting
PROBLEM
Difficulty in pumping
up the awning.
Part of the awning
does not inflate
Part of the awning does not deflate An isolation valve may have been closed. Locate and open.
The AirPoles are kinked
If you suspect an air leak
If you still suspect
an air leak
If you think your awning
has a water leak
If your awning has a water leak at
specific points/areas
If you think your awning has a
water leak at the beading that
attaches to the caravan
SOLUTIONS
1. The inflation valve is not fully screwed into the AirPole.
2. The deflation valves are open. Close.
3. Check the pump is working.
The isolation valves that connect the AirPoles may not be open.
Open all internal isolation valves and the air will flow into all the AirPoles. Do not close the
valves during normal use.
Add more air (9 psi).
1. Check that the inflation valve is properly closed and that the black 'O' ring seal is in place.
2. Check that the top cap on the inflation valve is done up tightly
3. Check that all the deflation valves are closed
Close all the isolation valves in the awning. Wait for a while and then check each AirPole for
pressure. If there is reduced pressure in any AirPole check the connecting hoses to make
sure that the isolation valves are done up tightly and are properly seated. If you still suspect
a leak it will be necessary to investigate the individual AirPole. See the AirPole repairing and
changing section of this manual.
Most suspected leakage is actually condensation (see condensation section of this
manual). This forms on the inside of the awning fabric. Try to increase the ventilation by
opening doors. A waterproof groundsheet will help stop moisture from the ground causing
condensation. The fabric, used to make this awning, has a massive hydrostatic head, so it is
extremely unlikely that it would leak.
The main seams of this awning have been factory taped to help prevent leakage (not All-
Season). Depending upon your expectations, it may be necessary to treat the remaining
seams with a seam sealant. Seam sealant should also be applied to areas where the taping
is damaged or has peeled away through wear and tear. It can also be applied to areas where
a leak may have developed. Kampa Dometic seam sealant is available from your dealer.
It is not possible to hot air tape the join between the awning and the keder beading.
Therefore we use a special waterproof sewing thread. This thread swells when wet to fill the
needle holes but the thread needs to become wet several times before it is totally effective.
This is known as 'weathering'.
12
DUKA-AIR-AWN-UG-11-19

Publicité

Table des Matières
loading

Table des Matières