Status.display; Technical.data - Becker BECK-O-TRONIC 5 pot.-frei Notice De Montage Et D'utilisation

Masquer les pouces Voir aussi pour BECK-O-TRONIC 5 pot.-frei:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Assembly and Operating Instructions
Yard light
Each.movement.of.the.roller.door.results.in.the.light.being.switched.on.for.2.minutes..
The.connection.of.the.yard.light.(light.bulb).is.carried.out.in.accordance.with.the.wiring.
diagram.
External control sensor (IMP)
An.external.control.sensor,.e.g..key-operated.switch,.can.be.connected.to.the.IMP.
terminals..This.control.sensor.has.the.switching.sequence:.Up,.Stop,.Down,.Stop,.
etc.
External 3-way pushbutton
A. 3-way. pushbutton. can. be. connected. to. the. terminals. 0V,. STOP,. Up. ( ). and.
Down.( ).
Photo cell (LS)
The.volt.free.relay.contact.(normally.closed).from.the.photo.cell.is.connected.to.the.LS.
terminals..Activation.of.the.photo.cell.stops.the.roller.door.and.the.door.travels.upwards.
briefly.(free.travel).
The.photo.cell.is.considered.as.object.protection.in.accordance.with.EN12453.
Emergency off switch.
If.a.safety.brake.is.used,.the.inbuilt.safety.limit.switch.can.be.wired.in.series.with.other.
external.safety.limit.switches.to.the.terminal.of.the.emergency.off.switch.
Meaning
Normal.mode
program.transmitter
Photoelectric.barrier.actuated.(LS).
Safety.edge.actuated.(SKS).
Emergency-Off.open
Safety.edge.input.defective
Dimensions.(W.x.H.x.D):..
Housing.material:..
Protection.class:...
Mains.connection:.
Capacity:.
Device.fuse:..
Switching.capacity:..
Lamp.switching.capacity:.
Temperature.range:.
Radio.frequency:.
18
Status display
Technical Data
155.x.130.x.50.mm
PC
IP20,.for.indoor.installation.only
230.V/50.Hz.(Type.of.connection.Y)
6.V.A
2.A.surge-proof
230.V/50.Hz.360.VA.or.24.V.DC.100W
230.V/50.Hz.max:.100.W
-10°.C.....+50°.C
433.MHz
LED
on
contin..flash
1x.flash
2x.flash
3x.flash
4x.flash

Publicité