4. Gas is leaking between the bottle and
the head.
See "During operation, gas is leaking
between the bottle and the head."
During operation, water and gas are leaking
through the outlet — pressure-relief valve is
engaged.
1. The siphon was overfilled.
"Release the pressure" and refill the
siphon.
Observe the maximum filling amounts.
Ensure the measuring tube is fully
inserted before filling.
2. Too many chargers were used.
Pay attention to the maximum number
of iSi soda chargers to be used indicated
in the Siphon Data.
During operation, gas is leaking between the
bottle and the head.
1. The head was not tightened securely.
Tighten the head onto the bottle
by hand as per the instructions.
2. Riser tube with gasket was not used.
"Release the pressure" and insert the
riser tube in the bottle.
3. The gasket has been damaged.
"Release the pressure." The riser tube
with gasket needs to be replaced and
is available as an original iSi spare part.
4. The bottle has been damaged on the upper
edge.
"Release the pressure." Send the siphon
to iSi or a service center.
12
Service.
Replacement parts are available individually
and at an affordable price.
See your specialist dealer for the availability of
replacement parts. In Austria, you can also get
in contact via info@isi.com. In the US contact
isinorthamerica@isi.com
Only send in the complete siphon for repairs.
Replacement parts can be seen in greater detail
on the expanded drawing.