DPA−...−CRVZS
Fitting mechanical components
Note
The screwing points for the profile plate must lie on the same level.
With pressure booster combinations DPA− −CRVZS5(10)(20):
S Align the product so that the condensate drain is at the bottom.
The manufacturing process leaves a layer of oxide on the inside of the reservoir
caps of the air reservoir CRVZS.
S For sensitive applications, use suitable filters between the air reservoir
CRVZS and other downstream−switched pneumatic devices.
Fasten the pressure booster combination via the grooves of the profile plate to
S
your system or machine stand.
mounting attachments from the profile kit system 5 for machine stands
slot nuts IPM−VN−05−15/M5−ST
edge cover for profile plate IPM−AN−05−20X40−PA
socket head screws M5 (strength min. 8.8, screw length: Stand thickness + 6 mm
screw−in depth. Tightening torque 5 Nm " 10 %)
Select suitable accessories from the catalogue www.festo.com/catalogue
Fitting pneumatic components
Note
The greater the pressure difference between P1 and P2, the higher the internal
air consumption.
S Limit the system pressure to 8 bar.
S Use short tubing at P1.
S Connect the system pressure of max. 8 bar to the input side in front of P1
without additional pressure regulators.
Connect the tubing and screw connectors
S
to the pneumatic connections P1 and P2
(è Fig. 3).
The exhaust procedure is performed using
the regulator.
Festo DPA−...−CRVZS 0806NH English
Fig. 3
P2
P1
21