FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V2.0.0

6.3. Register description

Once supplied with power, the Field Test Device will function according to the last saved configuration (factory settings if this is the first time the
device has been switched on, or if this configuration has not been changed).

6.3.1 Function register

Below is a list of the ranges accessible on the device (by default). These ranges make it possible to modify the device's behavior.
FR
Details on how each range functions can be found elsewhere in the table.
Range
S360
Activation or deactivation of the accelerometer
EN
S370
S371
S380
S382
S383
S385
S386
S387
S388
S389
S360 : Accelerometer
The accelerometer, when activated, enables the FTD to send a frame when there is a strong vibration (for example when the FTD is shaked).
S370 : Payload format
The Field Test Device (FTD) is compatible with the previous version of the device (the LoRaWAN Demonstrator). In order to modify the format of
the payload and to make it compatible with the previous device, it will be necessary to modify this range.
S371 : GPS configuration
The way in which the GPS module is configured is completely independent from the main firmware. Two functioning modes are available:
Permanent Mode
Periodic Mode
Content
Payload format
GPS configuration
Frame transmission period
ACK and Class mode
Uplink Port
Personalized Payload Size
Personalize Payload Text - Bloc 1
Personalize Payload Text- Bloc 2
Personalize Payload Text- Bloc 3
Personalize Payload Text - Bloc 4
Default value
0 : deactivated
0
1 : activated
0 : Format Legacy (Demonstrator)
1
1 : Format Field Test Device
0: GPS deactivated
1: GPS activated/Continuous Mode
11
11 : GPS activated/Continuous Mode + GPS Reset (Cold
Start)
0: No periodic transmission
600
1 to 86400 (expressed in seconds) : Periodic transmission
0: Class A Unconfirmed
1: Class A Confirmed
0
All other values will be retained.
1
1-223
0 : Deactivated
0
1 to 16 : Size of the payload
0
0
Each bloc allow to define 4 bytes of the payload
0
0
Comments