FIELD TEST DEVICE - LoRaWAN Europe - User Guide V1.2.0
Example of a set of commands and corresponding responses that can be seen on the terminal:
Syntaxe de la Commande
\FF\FF\FF\FF+++
ATS221=1
ATS214=0018B200
ATT63 PROVIDER
ATS214=0018B200
ATS215?
AT&W
ATO
GB
Interpreting the previous example: the user wanted to modify the start of the APP_EUI after having made an unauthorised command (answer
E), and the ranges were unblocked in order to modify the range. The second section of the APP_EUI was verified and the parameters were
saved before exiting. When exiting command mode, the device will make a JOIN request.

5.4. Register description

Once supplied with power, the Field Test Device will function according to the last saved configuration (factory settings if this is the first time
the device has been switched on, or if this configuration has not been changed).
ATS<n>=<m> or ATR type modification commands allow you to modify the content of these ranges.
It is essential to save the parameters using the AT&W command before exiting the command mode, otherwise all of your changes will be lost.
5.4.1 Fonction register
Below is a list of the ranges accessible on the device (by default). These ranges make it possible to modify the device's behaviour.
Details on how each range functions can be found elsewhere in the table.
Range
S370
S371
S380
S382
S383
Description
Input request in command mode
Transition request in OTAA activation mode
APP_EUI MSB modification change
Unblock the operating range
APP_EUI MSB modification change
Feeds back the value of the S215 range
Memory request for the state range
Output request in command mode
Content
Payload format
GPS configuration
Frame transmission period
ACK and Class mode
Uplink Port
Syntaxe de la réponse à la ligne suivante
CM
O
E -> This command is not validated (register no unlocked)
O
O
S200=44512451
O
O
Default value
0 : Format Legacy (Demonstrator)
0
1 : Format Field Test Device
0: GPS deactivated
1: GPS activated/Continuous Mode
11
11 : GPS activated/Continuous Mode + GPS Reset (Cold
Start)
0: No periodic transmission
600
1 to 86400 (expressed in seconds) : Periodic transmission
0: Class A Unconfirmed
1: Class A Confirmed
1
16: Class C Unconfirmed
17: Class C Confirmed
All other values will be retained.
1
1-223
Comments
Page
46
of 53

Publicité

loading

Ce manuel est également adapté pour:

Arf8123aab