OPTIONS AND ACCESSORIES
Changing the Setpoint Temperature — Digital
Temperature Controller
Units equipped with a digital temperature controller will heat up to
the setpoint temperature automatically when they are turned on.
Use the following procedure to change the setpoint temperature.
NOTICE
Built-in units must not have a setpoint temperature higher
than 200°F (93°C). Temperatures exceeding 200°F will
damage unit and void warranty.
NOTE: The temperature shown on the display may be inaccurate
when unit temperature is below 130°F (54°C).
1. Press the
key three times. The current setpoint
temperature will be shown on the
("SP" will be displayed after the second press).
2. Press the
key or
the setpoint temperature.
3. Press the
key to lock in the new setpoint temperature.
The
(temperature) display will go blank for two seconds
to show that the new setting has been accepted.
NOTE: After 10 seconds of inactivity during the programming
process, the controller will exit programming mode
automatically without saving any changes.
Up Arrow Key
Set Key
Digital Temperature Controller
Changing Fahrenheit and Celsius Setting — Digital
Temperature Controller
Use the following procedure to change between Fahrenheit and
Celsius on the display.
1. Press the
key once. Either an "F" for Fahrenheit or "C"
for Celsius will be displayed.
2. Press the
key or
between "F" (Fahrenheit) and "C" (Celsius).
3. Press the
key three times to lock in the new setting.
The
(temperature) display will go blank for two seconds
to show that the new setting has been accepted.
NOTE: After 10 seconds of inactivity during the programming
process, the controller will exit programming mode
automatically without saving any changes.
(temperature) display
key within 10 seconds to change
Down
Arrow
Key
Display
key within 10 seconds to change
Small Control Boxes
Two small-sized, flush mount control boxes are available for
the GRSSB model — the Mechanical Temperature Control
enclosure and the Digital Temperature Controller enclosure.
Both enclosures are installed using the following procedure.
ELECTRIC SHOCK HAZARD: Remote mounted control
box must be mounted on a vertical wall and installed
in vertical position. Mounting control box in horizontal
position may result in collection of liquids and lead to an
electric shock.
Do not modify wiring or cut thermostat capillary on
control box to increase remote mounting distance. Cutting
thermostat capillary will cause unit to overheat and may
damage unit as well as surrounding countertop.
Do not install remote mounted control box in an area
subject to temperatures above 29°C (85°F). Excessive
temperatures will cause control(s) to overheat, malfunction,
and fail.
1. Prepare the small control box opening. Make sure the
control box cutout is within reach of the 1829 mm (6')
control box conduit from the unit.
a. Refer to the "Small Control Box Installation Dimensions"
illustration for cutout and screw hole dimensions.
b. Perform the cutout and pre-drill the screw holes.
IMPORTANT NOTE
Make sure the installation location provides enough room for
electrical connections to the control box.
2. Install the unit into the countertop opening:
a. Pass the small control box through the countertop
opening.
b. Place the unit into the countertop opening.
3. Pass the small control box through the control box opening
so it can be mounted to the front of the mounting surface.
4. Position the small control box into the cutout opening from
the front.
• Align the holes in the control box with the pre-drilled
holes in the mounting surface.
5. Secure the small control box to the mounting surface using
four screws (not supplied).
Power I/O (on/off) Switch
Both remote mounted control boxes are equipped with a Power
I/O (on/off) switch. Move the Power I/O (on/off) switch to the I
(on) position to turn on the unit. The indicator light in the switch
glows when the unit is on.
16
English
WARNING
NOTICE
Form No. GRSSM-1020