Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Initial Set Up:
Once all the components of the Air Wash are installed
properly and all the motors are turning in the correct
rotation, we recommend the intitial settings of your
airwash be the following;
1) The adjustable air inlet (5) cover 1/2 of the diffuser
slots
2) The cascader slide gates (11) be fully open
Ensure there is sufficient suction at the grinder and run
some material. The more consistent the feed to the Air
Slots 1/2 Open
for Initial Set-up
6
11
Wash the better the cleaning of the regrind. Observe
the material being discharged underneath the
cascaders and the dust drum. Caution the drum will be
under pressure during operation, shut down equipment
prior to opening the dust drum lid. If the material is
satisfactory, set the position of the adjustable air inlet.
If more fines are to be removed, allow more air in at
the diffuser. If useable material is present in the dust
drum close off the air slots on the diffuser in 1/4 inch
intervals. When fine tuning your Air Wash, be sure to
change one variable at a time.