PROBLEM
No Solution Flow.
Solution Flow Does Not Stop.
Will Not Pick Up Any
Water From Floor.
Will Not Pick Up All Of The
Water From The Floor.
Runtime is less than when
new.
Cleaning Is Not Even.
Machine does not run.
NOTE: If any problems remain after taking the above steps, contact your local authorized distributor /
service station for further evaluation and repair.
TROUBLE-SHOOTING
CAUSE
Solution tank is empty.
Low battery charge.
Clogged filter.
The solution valve is closed.
Obstruction in the solution hose.
Solution valve or linkage damaged.
Solution hose kinked.
The solution valve is open.
Solution valve or linkage damage.
The solution valve is dirty.
Damaged seat and washer in valve.
The valve stem is dirty.
Hose disconnected or damaged between sol.
tank & valve.
Squeegee is up.
Squeegee hose is off or plugged.
Vac motor switch is off.
Recovery tank is full.
Vacuum shut-off float is stuck.
Obstruction / damage in the squeegee,
squeegee hose or standpipe.
Leaking over gasket.
Vac motor is not running.
Recovery drain hose not plugged properly.
Debris on squeegee blades.
Squeegee blade is worn / damaged.
Obstruction / damage in the squeegee,
squeegee hose, or standpipe.
Squeegee angle needs adjustment.
Vacuum motor worn out.
Recovery tank drain hose damaged.
Over charging batteries. (Charging too
frequently).
Tops of batteries are dirty / wet.
Battery terminals are dirty / damaged, or loose.
Electrolyte level is too low.
Batteries are not fully charged.
Charger is damaged.
Battery is defective or worn out.
Brush / pad is worn.
Damage to brush assembly; casters or
solution valve.
Circuit breaker tripped.
Battery cables loose or not connected.
Batteries not charged.
Battery charger was unplugged before the
charge cycle was completed.
SOLUTION
Fill the tank.
Charge the batteries.
Clean filter.
Open the solution valve.
Remove the obstruction.
Repair / replace the valve linkage.
Check for kinks and remove.
Close the solution valve.
Repair / replace the valve linkage.
Clean the solution valve.
Replace valve.
Clean and lubricate valve stem.
Reinstall or replace hose.
Lower squeegee.
Reinstall hose. Remove cap inside the
Recovery tank to clean hose restriction.
Turn vac motor switch "on".
Empty tank.
Open float valve/remove
obstruction.
Remove obstruction / repair damage.
Remove old gasket / replace.
Have an authorized serviceman repair.
Install drain hose plug properly.
Clean squeegee.
Reverse / replace squeegee blade.
Remove obstruction / repair damage.
Adjust angle.
Repair / replace vac motor.
Repair / replace recovery drain hose.
Monitor run time, and adjust charging
frequency accordingly.
Clean / dry, charge batteries.
Clean terminals, and connectors, replace
damaged cables. Charge.
Add distilled water after charging.
Charge batteries for 8 hours.
Have an authorized serviceman repair.
Check for fault codes on the battery charger
while batteries are charging.
Replace brush / pads.
Have an authorized serviceman repair.
Reset circuit breaker.
Check and connect or tighten.
Charge batteries.
Wait (up to five minutes) and try again.