Télécharger Imprimer la page

3M Protecta Viper 2 Manuel D'instruction page 9

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 79
SYSTEM SPECIFICATIONS
Maximum Arresting
Force:
Capacity:
Operating temperature:
Anchorage:
Lanyard Specifications:
Vertical Lifeline
Specifications:
Fall Clearance
Requirements
(Figure 4 and Figure 5):
Table 1: Protecta® Viper™ 2 Rope Grab and Rope
6 kN (1 349 lb)
100 kg (220 lb)
Minimum: -35 °C (-31 °F)
Maximum: 57 °C (134,6 °F)
Anchorage Strength requirements vary with the fall protection application.
Structure on which the Rope Grab is placed or mounted must meet:
EN795:2012
12 kN (2 698 lb)
Do not use a Energy-Absorbing Lanyard or a Restraint Lanyard with this equipment.
;
Only lifeline ropes which meet the size, construction, and material properties required
for compatible use with this rope grab may be used.
;
Knots shall not be used for load bearing end terminations, but may be an acceptable
means of securing the free end of the lifeline at ground level or attaching counterweight
at ground level.
Figure 4 illustrates how Rope Grab positioning affects Fall Clearance and Figure 5 specifies
these values.
9