Adeunis RF ARF 3-PRO Série Notice D'emploi page 41

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 7
IMPORTANT NOTES
«ERROR_1»: message returned when a user inserts an unauthorised value for the S200 register (in the light of
current regulations).
«WARNING_1»: message returned when a user inserts an authorised value for the S200 register, but the
content of the S231 register is not compatible with the maximum power permitted for the channel selected. As
a consequence, the S231 register is automatically updated with the maximum permitted value for the channel
selected.
«WARNING_2»: message returned when a user inserts a value that is available but not authorised for the S231
register (in the light of the maximum permitted power for the channel selected). As a consequence, the S231
register is automatically updated with the maximum permitted value for the channel selected.
Users must use the «AT&W» command if they wish to save the update.
Type
Serial link
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
208210A_UG_V1.0_ARFx3-PRO
Register
Function
S210
Transmission rate
S211
Data length
S212
Parity
S213
Stop bits
S214
Timeout command
S215
Type of interface
S216
Handshake
S219
RS485 delay
Description
Transmission rate of the serial link
in bits/s
«0»: 600
«1»: 1200
«2»: 2400
«3»: 4800
«4»: 9600
«5»: 19200
«6»: 38400
«7»: 57600
«7»: 7 bits
«8»: 8 bits
«1»: none
«2»: even
«3»: odd
«1»: 1 stop bit
«2»: 2 stop bits
Length of timeout for detecting ***,
in ms from 3 to 240
«0»: RS232 only
«1»: RS232 or RS485 (DE/RE
lines managed)
«0» : hardware, RTS (limited to the
addressed protocol)
«2»: none
Delay between DE activation and
the first RS485 byte transmitted
from 0 to 160
Default value
Note
4
1.2 & 5
8
5
1
5
1
5
3
1
1
3
GB
41

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Arf33-proArf43-proArf53-pro

Table des Matières