Special Operating and Cleaning Instructions for Institutional Use
Preparing Infant Formulas and Similar
Nutritional Adult Products
Refer to the instructions for installing and mixing
with the cutting blades. Be sure that the mixer and
any containers have been properly cleaned and
sanitized before using.
Follow the additional guidelines below:
1. Always clean the cutter attachment thoroughly
by removing the attachment and washing with
detergent. This helps avoid cross-contamination
between different formula types.
2. Measure powder or liquid ingredients for the
formula mixture. Add half of the final volume
of water.
3. Mix formula for 15–60 seconds on LOW (1) power
until thoroughly blended.
4. Add remaining water and blend 15–30 seconds
on LOW (1) power.
NOTE: Some formulas may require using a
slightly longer blending time or HIGH (2) power.

Troubleshooting Guide

Problem . . .
Immersion mixer will
not turn on
Excessive noise
or vibration
Motor strains or stops
Poor results
(See also Tips)

Accessories

Part Number
HMIA 200B
Solution . . .
• Make sure the mixer is plugged in.
• Check for a blown fuse.
• Make sure that the blade assembly is properly installed.
• Make sure that the blade does not contact the sides or bottom of the container.
• Reduce the amount of product in the bowl. Mix thick products in smaller batches.
• Make sure ingredients are prepared properly for mixing.
• Reduce the amount of product.
• Process for a longer or shorter period of time.
• Adjust the mixing speed.
Description
Detachable blade/shaft assembly
Special Cleaning Instructions for
Hospital and Institutional Use
To ensure that the mixer and blades remain sanitary,
follow the special cleaning instructions below.
1. Wash the cutter attachment as described in the
section "General Cleaning With the Attachment
in Place" on page 6.
2. At least once per day, sanitize the cutter
attachment per the "Sanitizing" instructions
on page 6, or as required to meet local
sanitation codes.
3. After cleaning, attachments should be air-dried
and stored in a closed container or wrapped to
protect them from contamination.
The cutter attachment may also be washed and
autoclaved by the hospital's central processing
department. Be sure to follow all required safety
and sanitation codes.