ROUBLESHOOTING
Fault
The fire does not burn well
Glass gets dirty quickly
There is a paint smell and smoke
Condensation
Smoke nuisance
Chimney fire
Cause
Wood is too damp
Wrong fuel
Chimney draught too weak (min. 12 Pa)
Insufficient combustion air
Wood is too damp
Wrong fuel
Too much wood used
Insufficient combustion air
The coating is drying out
Large temperature difference
Chimney draught too weak (min. 12 Pa)
Fuel is not entirely used up
Wrong fuel
Overloading
Poor maintenance
Solution
Check, max. residual moisture 20%
Only use the permitted fuels for the appliance
Check the outlet is airtight
Light fire in the chimney
Close any open doors on other appliances
connected to the chimney
Seal any cleaning hatches in the chimney
If necessary, clean the connector
Check air flow and diameter of flue connections
Check ventilation fittings and extractor hood, if
necessary open windows
Check, max. residual moisture 20%
Fuel not small enough, ensure max. size
Only use the permitted fuels for the appliance
Do not use more 2 or 3 pieces of wood at once
Connect combustion air feed directly to the
appliance and extract to the circulation grid
or directly to outside
Check diameter of circulation
Check ventilation fittings and extractor hood, if
necessary open windows
There is a smell when the stove gets very hot.
Disappears after a while.
Open the door a chink while the stove warms
up. Do not leave the appliance unattended!
Check the outlet is airtight
Light fire in the chimney
Close any open doors on other appliances
connected to the chimney
Seal any cleaning hatches in the chimney
If necessary, clean the connector
Fuel should only be added when there is no
orange flame visible in the stove.
Shut off the air flow immediately and call the fire
brigade