8
T
ROUBLESHOOTING
Storing
The fires burns really bad The wood is too wet
Window gets dirty really
quick
Signs of smoke at first use of
the stove
Moisture
Too much smoke
Chimney fire
62
Oorzaak
Wrong fuel
Chimney draught is too weak
(min 12 Pa)
Too little combustion air
The wood is too wet
Wrong fuel
Too many wood
Too little combustion air
The base paint is drying out
High temperature difference
Chimney draught is too weak
(min 12 Pa)
Fuel hasn't burnt completely
Wrong fuel
Too much fuel
Bad maintenance
Oplossing
Use
dry
Humidity max. 20%
Only
use
suitable
Respect the right quantity of wood
Check the density of the exhaust pipe
Clean the chimney
Check the diameter of the smoke outlet
and
air
Check all ventilation in the house, if
necessary open window
Use
dry
Humidity max. 20%
Logs
aren't
small
Use only the right wood
Don't refill more than 2-3 pcs max.
Check the diameter of the air supply
Install an extra air supply conduct
Shut down the ventilation system of the
house
Disappears after a while. Is harmless
Open the door of the stove a little
when
starting
to
Stay near the stove
Check the density of the exhaust pipe
Clean the chimney
Only refill wood in the stove as long as
there are nog more orange flames
visible.
Shut down the air supply immediately
and call your local fire department
wood
:
wood
supply
wood
:
enough
heat
up