Troubleshooting
NOTE: A few drops of water may leak at o-ring when first installed. This should stop
when o-rings are under pressure and seal properly.
Before beginning any troubleshooting
•
Turn inlet valve off.
•
Relieve pressure by opening flush valve and
pushing the red pressure relief button.
Issue: Leak between threaded connections
Issue: Leak between fittings and filter head
Option 1:
Option 2:
Replace o-rings if the unit still leaks.
1. Remove fittings.
2. Apply additional thread sealant compound.
3. DO NOT over tighten fittings!
1. Remove retainer clip carefully. A screwdriver may be
necessary to pry the fitting out. Check carefully for
any cracks. If damaged, discard and use a new one.
2. Gently remove leaking fitting.
3. Apply additional food grade lubricant to o-ring and
reinsert fitting.
4. Reinsert retainer clip by pushing down into position.
14