Remote panel
This allows the control panel to be placed at a certains distance from the Blocksystem; for
example, alongside the coldroom door (max. distance 100m).
Water condensation
UK
This is obtained by replacing the air-cooled condenser with a water-cooled one.
To connect water condensers, it is necessary to use pipes with a diameter of no less than those
already connected to the Blocksystem, respecting the inlets and outlets. If the machine is sized
for condensing using tower water, the inlet pipe is formed by a coupling that connects the two
pipes with smaller sections of the condenser. When condensing is to be carried out using cistern
water, the inlet pipe can be distinguished by the fact that it has a barostatic valve to regulate water
flow.
Install the shut off valve of the water mains nearest to the operator.
Never close the water shut off valve while the appliance is operating.
To improve the performance and duration of the machine, check the following:
PLEASE NOTE: the water pipes must be protected against low outside temperatures.
Voltage monitor
This device is used to protect the Blocksystem from voltage increases or dips.
• Differential thermomagnetic switch
This device protects the Blocksystem against overloads, short circuits and indirect contact.
Different voltage
Additional electronic module for master/slave operation
Additional electronic module for monitoring ,recording and remote management
Remote management system
compressor to evaporate.
the water temperature must be between 20 and 30°C for water-condensed units using
-
tower water and between 5 and 20°C for water-condensed units using cistern water
water pressure must be between 1 and 5 bar.
-
Used to connect 2 Blocksystem units together in a cold room with the possibility for
synchronised operations (defrost, Blocksystem operation and temperature alarms display)
Makes it possible to connect the Blocksystem to a remote management system
Used to monitor and programme the Blocksystem from a PC or data recorder. It makes
advanced management possible (communication via modem or GSM) for all Blocksystem
alarms.
Es: FSM009Z001
1
230/1/50 Hz
2
400/3/50 Hz
3
110/1/60 Hz
4
220/3/60 Hz
5
220/1/60 Hz
6
460/3/60 Hz
8
230/3/50 Hz
BLOCKSYSTEM FS Pag. 34 Rev. 02 02/07