EN
Troubleshooting
Problem
No function when Throttle Trigger
(4) is operated. Oscillating Spindle
(1) rotates freely
Oscillating Spindle (1) performance
is restricted, yet air flows freely
from the tool
Seized Oscillating Spindle (1)
Sander will not turn off when
Throttle Trigger (4) is released
8
Possible Cause
Air supply issue
Defective Throttle Trigger or throttle components
Internal vane seized
Broken internal vane
Defective internal Throttle Trigger components
If the above troubleshooting solutions fail, contact your dealer or an authorised Silverline service centre.
Solution
Check all connections between compressor and tool, and ensure the operating
pressure is set correctly
In the event the internal throttle mechanism becomes jammed, check for dirt
within the Air Inlet (6) and remove. Pour a small amount of air tool oil (not
included) into the Air Inlet, reconnect the air supply and operate the Throttle
Trigger in small bursts. If the tool still ceases to function, return to an authorised
Silverline service centre
Disconnect the air supply. Pour a small amount of air tool oil (not included)
into the Air Inlet (6), reconnect the air supply and operate the Throttle Trigger in
small bursts. Periodically tap the Spindle Housing (2) using a rubber mallet (not
included). If the tool still ceases to function, return to an authorised Silverline
service centre
Return to an authorised Silverline service centre
Return to an authorised Silverline service centre