OPERATION AND MAINTENANCE INSTRUCTIONS
FOR 9000 SERIES
ROOF TOP AIR CONDITIONERS
AND
CEILING PLENUMS
MODE D'EMPLOI ET UTILISATION
DES CLIMATISEURS DE TOIT DES
SÉRIES 9000 ET
PLÉNUM DE PLAFOND
RV Products
A Division of Airxcel, Inc.
P.O. Box 4020
Wichita, KS 67204
1976A368 (12-02) PP

Publicité

loading

Sommaire des Matières pour Airxcel RV Products 9000 Série

  • Page 1 FOR 9000 SERIES ROOF TOP AIR CONDITIONERS CEILING PLENUMS MODE D’EMPLOI ET UTILISATION DES CLIMATISEURS DE TOIT DES SÉRIES 9000 ET PLÉNUM DE PLAFOND RV Products A Division of Airxcel, Inc. P.O. Box 4020 Wichita, KS 67204 1976A368 (12-02) PP...
  • Page 2 TABLE OF CONTENTS General Information ............Standard Ceiling Plenum Control Panel .
  • Page 3 FIGURE 1 SECTION III - OPERATION For Cooling (Refer to Figure 1, page 3). Operation During Cooler Nights (Cooling Operation). Turn the selector switch to the “LOW COOL” or “HIGH COOL” position. It is important, when the outdoor temperature drops in the evening or during the night to below 75 degrees F, that the Rotate the thermostat (temperature control) to the thermostat (temperature control) be set at a midpoint between...
  • Page 4 temperature of the air entering the air conditioning III. Short Cycling unit drops below this setting a few degrees and When an air conditioner is in operation, its compressor automatically turns off when the temperature of the circulates refrigerant under high pressure. Once off, it will air entering the air conditioner rises a few degrees take two to three minutes for this high pressure to equalize.
  • Page 5 Check Points - Failure to start or to cool the air are Cleaning and/or changing the filters with 8000 series ceiling assemblies sometimes problems with air conditioning units. The RV Products RV air conditioner is designed to Disengage the two 1/4-turn fasteners that secure the operate on 115 volt electrical power.
  • Page 6 The blower drive motor on some units may include oiling However, if lubrication to the unit is desired, use only SAE cups at the top of the motor. There is no requirement to 20 non-detergent type oil. DO NOT OVER OIL - three to oil the journals under normal operating conditions.
  • Page 7 All written correspondence should be directed to: must be made within ninety (90) days of the original purchase. RV Products A Division of Airxcel, Inc. Inquiries about your RV Products air conditioner P.O. Box 4020 must include the model and serial numbers and the Wichita, KS 67204 date of purchase.
  • Page 9 TABLE DES MATIÈRES Renseignements généraux ........... . . 9 Panneau de contrôle de plenum de plafond standard .
  • Page 10 SECTION III - FONCTIONNEMENT Pour le refroidissement (se reporter aux figure Le compresseur du climatiseur est incapable de démarrer contre une haute pression, donc, lorsque le climatiseur est 1, page 3) Placer le sélecteur à la position «LOW COOL» arrêté, il est important de la laisser arrêter pendant deux à (refroidissement faible) ou à...
  • Page 11 que la température de l’air soit moins élevée lorsque Placer les aérateurs dans la direction voulue pour les aérateurs sont entièrement ouverts, la capacité de l’écoulement de l’air déchargé. chauffage sera encore la même. REMARQUE Pour la circulation d’air seulement (se reporter aux figure 1, page 3) Lorsque le sélecteur est en position «LOW FAN»...
  • Page 12 RV Products plateau situé à la partie inférieure du climatiseur de toit. A Division of Airxcel, Inc. Ces informations figurent aussi sur la plaque signalétique P.O. Box 4020 du climatiseur.