Electrical Connection - Asco JOUCOMATIC SENTRONIC 601 Série Manuel D'installation

Servodistributeurs à commande analogique pour application sur le vide
Masquer les pouces Voir aussi pour JOUCOMATIC SENTRONIC 601 Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

G 1/8 (Ø 3 mm) G 1/4 (Ø 6 mm) - G 1/2 (Ø 12 mm) - G1 (Ø 20 mm)
View on the soldered wire
side of female connector
SETTING
0 - 10V
Output
ADJUSTABLE
or
BY POTENTIOMETER
Input*
PRESSURE SWITCH OUTPUT
OR
OR
*
External feedback value input if the valve is configured for external sensor
WARNING:
1) It is necessary to use a 24 V DC ±10% power supply tolerance with 10% max. ripple
(no supply per diode bridge). Over voltage or a ripple rate of over 10% can damage
the electronics.
2) Max. current of pin 7 is 500 mA (output NPN/PNP). Pin 7 has a short-circuit and
overload protection.
3) If a relay (inductive load) is connected to the pressure switch output, a freewheel diode
or varistor must be used.
4) Do not solder to unused pins on the female connector.
5) Grounding for personal protection must be done at the PE-thread (ØM4) on the body.
6) Use a shielded cable for EMC-protection.
Connect the shield to ground and to the connector body.
WIRING CONNECTOR
ON SENTRONIC WITH ANALOGIC CONTROL
VACUUM FEEDBACK
0 - 10 V (or 0-20mA or 4-20mA)
500
500
500
500
GB
PE
ØM4
2
17

Publicité