Declaration Of Conformity; Certification - Bosch GKE 35 BCE Professional Notice Originale

Masquer les pouces Voir aussi pour GKE 35 BCE Professional:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 42
OBJ_BUCH-716-001.book Page 32 Tuesday, January 13, 2009 3:26 PM
32 | English

Declaration of Conformity

We declare under our sole responsibility that
the product described under "Technical data" is
in conformity with the following standards or
standardization documents: EN 60745 accord-
ing to the provisions of the directives
2004/108/EC, 98/37/EC (until 28 Dec 2009),
2006/42/EC (from 29 Dec 2009), 2000/14/EC.
EC Type Certification No. 212 26 95.00 by noti-
fied testing agency No. 0344.
2000/14/EC: Measured sound power level
103 dB(A).
Conformity assessment procedure according to
Annex V.
Technical file at:
Robert Bosch GmbH, PT/ESC,
D-70745 Leinfelden-Echterdingen
Leinfelden, 01.08.2008
Dr. Egbert Schneider
Dr. Eckerhard Strötgen
Senior Vice President
Head of Product
Engineering

Certification

Robert Bosch GmbH, Power Tools Division
D-70745 Leinfelden-Echterdingen
01.08.2008
Assembly
For Your Safety
¢ Warning! Switch off, remove plug from
mains before adjusting, cleaning or if cable
is cut, damaged or entangled.
¢ Caution! Do not touch the rotating chain.
¢ Do not operate the chain saw near other
people, children or animals. Do not operate
the chain saw after drinking alcohol or un-
der the influence of intoxicating drugs or
medication.
1 609 929 P88 | (13.1.09)
Your machine is double insulated for safety and
requires no earth connection. The operating
voltage is 230 V AC, 50 Hz (for non-EU countries
220 V, 240 V as applicable). Only use approved
extension cables. Contact your Bosch Service
Centre for details.
When operating the chain saw with an extension
cable, the following conductor cross-sections
are required:
2
- min. 1.5 mm
to a max. cable length of 50 m
2
- min. 2.5 mm
to a max. cable length of 100 m
Note: If an extension cable is used it must be
earthed and connected through the plug to the
earth cable of your supply network in accord-
ance with prescribed safety regulations.
When using cable drums, these must be com-
pletely unreeled.
Only extension cables of design type H07 RN-F
or IEC (60245 IEC 66) are permitted for use.
If in doubt contact a qualified electrician or the
nearest Bosch Service Centre.
WARNING! Inadequate extension cables can
be dangerous. Extension cable, plug and sock-
et must be of watertight construction and in-
tended for outdoor use.
Cable connections should be kept dry and off
ground.
It is recommended for increased electrical safe-
ty to use a Residual Current Device (RCD) with
a tripping current of not more than 30 mA. Al-
ways check your RCD every time you use it.
If the supply cord is damaged, it must be re-
placed by a Bosch Service Centre.
For products not sold in GB:
WARNING: For your safety, it is required that
the plug attached to the machine is connected
with the extension cord. The coupling of the ex-
tension cord must be protected against splash
water, be made of rubber or coated with rubber.
The extension cord must be used with a cable
strain relief.
Bosch Power Tools

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Gke 40 bce professional

Table des Matières