Télécharger Imprimer la page

Kichler Lucian II Manuel D'instructions page 15

Publicité

Les langues disponibles

Les langues disponibles

TROUBLESHOOTING
Problem
Solution
Fan will not start.
1. Check circuit fuses or breakers.
2. Check all electrical connections to ensure proper contact. CAUTION: Make sure the main
power is OFF when checking any electrical connection.
Fan sounds noisy.
1. Make sure all motor housing screws are snug.
2. Make sure the screws that attach the fan blade brackets to the motor are tight.
3. Make sure wire nut connections are not rubbing against each other or the interior wall of the
switch housing. CAUTION: Make sure main power is off.
4. Allow a 24-hour "breaking-in" period. Most noise associated with a new fan will disappear
during this time.
5. If using an optional light kit, make sure the screws securing the glassware are tight. Make sure
the light bulbs are not touching any other component.
6. Do not connect this fan to wall mounted variable speed control(s). They are not compatible
with ceiling fan motors or remote controls.
7. Make sure the upper canopy is a short distance from the ceiling. It should not touch the ceiling.
Fan wobble.
1. Check that all blade and blade arm screws are secure.
2. Most fan wobbling problems are caused when blade levels are unequal. Check this level by
selecting a point on the ceiling above the tip of one of the blades. Measure this distance. Rotate
the fan until the next blade is positioned for measurement. Repeat for each blade. The distance
deviation should be equal within 1/8".
3. If the blade wobble is still noticeable, interchanging two adjacent (side by side) blades can
redistribute the weight and possibly result in smoother operation.
42" , 52" and 60" Lucian II | 15