8. TROUBLE SHOOTING
Perform regular inspections on the machine in order to ensure efficient operation of the machine. For a complete
service, we recommend to take the machine to your service center.
Symptoms
Cleaner will not start
Loss of suction
Dust discharging fromexhaust 1. Filter not installed/not
In case of not being able to solve the problem, take your machine in for service.
To locate the after-sales service nearest to you, please contact the point of sale where you purchased the
machine.
Possible Cause(s)
1. No power at receptacle
2. Protective device enabled
3. Defective switch
4. Defective motor
1. Loose hose connection
2. Filter clogged
3. Wire screen clogged
4. Full tank
5. Hose clogged
installed properly
2. Filter damaged
3. Filter not functional
29/104
Corrective Action
1. Check for power
2. Review operation section in
manual
3. Replace Power Unit
4. Replace Power Unit
1. Tighten hose connection
2. Clean or replace filter
3. Clean wire screen
4. Empty tank
5. Clear obstruction
1. Properly install filter
2. Replace filter
3. Clean or replace filter
English