Télécharger Imprimer la page

Samsung Pure Cycle WF231 Serie Informations Techniques page 5

Publicité

Les langues disponibles

Les langues disponibles

ALIGNMENT AND ADJUSTMENTS
To avoid risk of electrical shock, personal injury or death; disconnect power to washer
before servicing, unless testing requires power.
Quick Test Mode:
EEPROM Clear Check
Definition of EEPROM Clear Mode:
- EEPROM initialization.
- All course/option settings are to be reset to default
values after EEPROM initialization.
- When Service arises and it needs PCB replacement,
EEPROM should be reset.
How to Enter:
- The unit needs to be on.
- Press Delay Start Key, and Power Key at the same
time.
[BingBang2] Technical_information_02830C-01_EN.indd 5
WARNING
1. All LED's light up and it sends out Beep Sound when it
enters into the Quick Test Mode. (Including 7-Segment)
2. Displays software version for a sec and Clear EEprom. (Ex. If
S/W Version is 49, 7-Segment will display LP07)
3. When the version is displayed, turn the Jog-Dial so that
the version disappears. Press the following keys to test the
various components.
- Temp Key : Water Valve Test
- Spin Key : Door Lock/Unlock Test
- Soil Key : Water Heater Test
- Signal : Drain Pump Test
5
2012-10-05
3:26:48

Publicité

loading

Ce manuel est également adapté pour:

Pure cycle wf241 serie