5.2. TWO-HOUSEHOLD SYSTEM

OP4
2
2
OP5
A2
2
OP1
2
OP6
(1) For jumper and dip-switch confi gurations see sections 7.3 and 7.4
5.2.1.

MAXIMUM DISTANCES BETWEEN DEVICES

Basic system with 2 video door phones and distributor
Segment
A2 - most distant video door phone
C2 – most distant video door phone
D – most distant video door phone
C1 – C2
A2 - OP1
A2 - OP4
A2 - OP5
A2 - OP6
B - OP2
OP3 - C3
System up to 8 video door phones and distributor
Segment
A2 - most distant video door phone
C2 – most distant video door phone
D – most distant video door phone
C1 – C2
A2 - OP1
A2 - OP4
A2 - OP5
A2 - OP6
B - OP2
OP3 - C3
DS1722-125
2
2
C2
2
Master 1
C1
OP3
110-230 V~
Household
Slave
1
OP3
Slave
OP3
Slave
2Voice cable
(Ø 0,8mm)
150m
-
50m
0,5m
20m
50m
20m
20m
20m
20m
(*) SYT1 wire contains two pairs of wires inside. Use both to reach a distance of 20 m.
2Voice cable
150m
-
50m
0,5m
20m
50m
20m
20m
20m
20m
(*) SYT1 wire contains two pairs of wires inside. Use both to reach a distance of 20 m.
D
2
B
OP2
2
2
(1)
C3
2
2
110-230
V~
2
(1)
C3
2
2
110-230
V~
2
(1)
C3
2
2
110-230
V~
SYT1
1mm
West Pen
2
cable D980
130m
130m
50m
-
50m
50m
0,5m
0,5m
10m (*)
20m
50m (*)
50m
10m (*)
20m
10m (*)
20m
30m (*)
30m
20m
20m
SYT1
1mm
West Pen
2
(Ø 0,8mm)
cable D980
100m
130m
40m
-
-
50m
0,5m
0,5m
10m (*)
20m
50m (*)
50m
10m (*)
20m
10m (*)
20m
30m (*)
30m
20m
20m
B
2
Master 2
2
(1)
C3
OP3
2
Slave
2
(1)
C3
OP3
2
Slave
2
(1)
C3
OP3
2
Slave
Type of wire
1mm
single
Ø 0.6 mm twisted telephone
2
cable
wire without sheath
100m
100m
30m
40m
-
0,5m
0,5m
20m
10m
50m
50m
20m
10m
20m
10m
30m
30m
20m
10m
Type of wire
1mm
single
Ø 0.6 mm twisted telephone
2
cable
wire without sheath
100m
100m
-
15m
30m
0,5m
0,5m
20m
10m
50m
50m
20m
10m
20m
10m
30m
30m
20m
10m
OP2
2
110-230
Household
V~
2
2
110-230
V~
2
110-230
V~
CAT5 / CAT6
60m
15m
-
-
0,5m
10m
30m
10m
10m
10m
10m
CAT5 / CAT6
60m
15m
-
-
0,5m
10m
30m
10m
10m
10m
10m
25