ProMark
ITem
DeScrIpTIoN
1
Dashboard
2
Relief valve / bleed hose
3
Hydraulic motor shutoff
valve
4
Solvent flush valve
5
"B" side spray material
shutoff valve
6
"A" side spray material
shutoff valve
7
2nd gun shutoff valve (2-gun
units only)
8
Pressurized bead dispenser
regulator
9
Solvent flush regulator
10
Solvent flush relief valve
fuNcTIoN
The dashboard contains the engine ignition key, the engine throttle, the pressure control knob (to
determine spraying pressure and can be used to fine-tune the spraying pattern) and the pressure
gauges for both the "A" side and "B" side. See section 3.4 for further details.
This is the relief valve for both "A" and "B" sides of the system. When it is open (horizontal), spray
material will circulate from the material container through the siphon hose and back to the container
through the bleed hose. When it is closed, the system will build spraying pressure.
This valve will cut off the flow of hydraulic fluid to the hydraulic motor when closed.
usage note: This valve should remain open when the system is running.
usage note: To adjust the speed of the hydraulic motor (and subsequently the spraying pressure), it
is recommended that the pressure control knob on the dashboard be used for this, NOT the hydraulic
motor shutoff valve. Using the hydraulic motor shutoff valve to adjust the motor speed will put
unnecessary wear on the valve.
Provides solvent to the mixing block, mixing tube and spray guns when needed.
usage note: This valve should remain closed until the system is ready to be flushed.
The "B" side spray material shutoff valve will cut off the flow of "B" side spray material to the mixing
block when closed.
usage note: This should remain open during spraying and closed whenever performing a solvent
flush.
The "A" side spray material shutoff valve will cut off the flow of "B" side spray material to the mixing
block when closed.
usage note: This should remain open during spraying and closed whenever performing a solvent
flush.
This valve will cut off the flow of the spray mixture to the outside spray gun, allowing the user to
perform 1-gun operations. Always make sure to perform a solvent flush before shutting down one of
the spray guns.
This allows the user to adjust the bead dispenser pressure.
usage note: A reading of 30-40 PSI is a recommended starting point. Follow the manufacturer's
recommedations.
This allows the user to adjust the solvent flush pressure.
usage note: A reading of 100 PSI is recommended whenever performing a solvent flush.
This valve allows pressure to build up inside the solvent flush tank. This is the blue valve located at the
very bottom of the solvent flush tank and can be accessed via the rear of the unit.
usage note: Generally, this valve should remain closed even when not performing a solvent flush, as
the solvent flush valve (item 4) will be the primary delivery point of the solvent.
description of unit
13