Mechanical installation
Fig. 19
Test dimensions and reference dimensions
16. Check of the correct setting (nominal dimension 1.05 ... 1.15 mm):
-
For this purpose, position two feeler gauges of the same thickness (e.g. 1.1 mm) for each tension
rod between the hexagon nuts and the complete stator and ensure that the feeler gauges can be
easily moved.
17. Correct the setting if necessary until both feeler gauges can be moved by the same force.
18. Check that the manual release functions properly. Attach pipe sections onto the levers and press them
together to check whether the motor shaft can rotate freely.
19. Connect the Bowden cable (not included in this delivery) and pull until the motor shaft can be freely ro-
tated.
NOTICE
The actuation force between the Bowden cable's hanging points is approximately 900 N. The
actual pull force required may be higher depending on the characteristics and position of the
cable.
INTORQ | BA 14.0196 | 04/2016