Télécharger Imprimer la page

Wittur WSG-S2.4 Instructions De Service page 65

Publicité

Mechanical installation
NOTICE
If a manual release is to be installed, the procedure described in section 4.5.2 (Step 2) must be
carried out now!
Assembly of the second stator
Fig. 10
Assembly of the stator
1
3
13. Push the complete stator onto the shaft.
14. Align the through holes in the complete stator (1) to the threads of the fastening bore holes in the first
stator.
15. Evenly tighten the brake with the six socket head cap screws (10) included in the scope of supply in sev-
eral runs using a torque key.
16. Establish the electrical connection and energize the brake (
17. Use a torque key to re-tighten the supplied fixing screws (10) with the required tightening torque
(
16).
18. Switch off the power.
INTORQ | BA 14.0196 | 04/2016
NOTICE
Only in the case of rotors with mounting paste on their gear teeth:
❚ Remove cover films from both front ends of the rotor.
❚ Protect friction surfaces against contact with mounting paste!
❚ After the mounting, excessive mounting paste must be removed properly!
3
1
10
10
Stator, complete
Complete rotor
15
6
1
10
10
6
Flange
10 Fixing screws
15 End shield
35).
27

Publicité