FLUE TYPE
COAXIAL SYSTEMS
B32 - C12 - C32
FLUE TYPE
COAXIAL SYSTEMS
B32 - C12 - C32
WITH ADAPTER "S"
FLUE TYPE
TWIN-PIPE
C12 - C32
WARNING!
For each 90 ° bend it is necessary to remove 1 meter from the total available length
Separate discharge and suction are prohibited on the wall or roof and in any case in pressure
areas diff erent. The drain and intake must not be positioned on opposite walls.
The smoke outlet is generally placed in the rear part, but it can also be placed laterally with 90
° angles. For positioning, proceed as follows:
• Undo the fi xing screws of the fume hood assembly;
• Rotate and reposition the fume hood assembly on the water heater, making sure that the
wiring cables (fan and pressure switch) do not interfere with the air conveyor (C);
• Fasten the fume hood assembly to the water heater by tightening the screws.
Important: check that the unit is perfectly inserted in the fl ue pipe.
• Insert the fl ue gas diaphragm between the fl ue hood unit and the exhaust pipe.
WARNING!!
AVOID THAT THE WIRING OBSTRUCTS
THE AIR PIPE C
FAN OUTLET
USCITA
POSITION
VENTILATORE
Maximum Extension Exhaust-air
MIN [m]
>0,5
>2
>3
Maximum Extension Exhaust-air
MIN [m]
>0,5
>2
Maximum Extension L1 suction/L2 fl ue gas
MIN [m]
>0,5
>10
CLIP A
90°
180°
270°
L MAX [m]
2
3
4
L MAX [m]
2
3
L1+L2=L MAX [m]
10
20
D
C
POSIZIONE CAVI
WIRING POSITION
CLIP B
DIAPHRAGM
DIAMETER
FLUE (D)
OF PIPE
[ø]
ø [mm]
46
48
60/100
NO Diaphragm
DIAPHRAGM
DIAMETER
FLUE (D)
OF PIPE
[ø]
ø [mm]
48
60/100
NO Diaphragm
DIAPHRAGM
DIAMETER
FLUE (D)
OF PIPE
[ø]
ø [mm]
43
80/80
48
90°
270°
CLIP B
CLIP A
GB
180°
35