SP EC I FI C AT IO N S

Installation Requirements

For portable applications, Wolf grill carts are designed spe-
cifically to fit grill models ICBOG30, ICBOG36 and ICBOG42
and the side burner. Model ICBOG54 is designed for built-in
applications only.
For built-in applications, Wolf outdoor grills and the burner
module are designed for easy placement into a built-in
enclosure. For outdoor grills, installation in a combustible
enclosure requires an insulating liner. For the burner module,
an insulating liner is not required. The enclosure should be
built according to specifications for your specific installa-
tion on page 6. If the burner module is installed next to an
outdoor grill, a minimum of 305 mm is required between
units. A rotisserie side conversion kit is available from an
authorized Wolf dealer.
Grill carts, insulating liners and stainless steel doors and
drawers are avail able through an authorized Wolf dealer.
4 | English
Electrical
Installation must comply with all applicable electrical codes
and be properly grounded (earthed).
The electrical outlet must be located within reach of the
power cord. A separate circuit, servicing only this appliance
is required.
IMPORTANT NOTE:
A ground fault circuit interrupter (GFCI)
or residual current device (RCD) is required to reduce the
risk of electrical shock.
E LECTR ICAL R EQUI R EM ENTS ( G RI LL | M ODULE)
Electrical Supply
grounded, 220-240 VAC, 50/60 Hz
Service
Receptacle
3-prong grounding-type, IEC inlet
E LECTR ICAL R EQUI R EM ENTS ( R OTI S SE RI E )
Electrical Supply—Input
grounded, 220-240 VAC, 50/60 Hz
Electrical Supply—Output
Service
0.5 A (6 Watts)
Receptacle
barrel plug, 2.1 mm ID x 5.5 mm OD
WARNING
FOR AUSTRALIA ONLY:
This appliance is supplied with a cord and can be hard
wired to a terminal box or plug. Do not remove the
ground (earthed) plug .
N (BLUE)
P (BROWN)
E (GREEN/YELLOW)
IMPORTANT NOTE:
Connection of this appliance should be
through a fused connection unit or a suitable isolator, which
complies with national and local safety regulations. The
on/off switch should be easily accessible after the appli-
ance has been installed. If the switch is not accessible after
installation (depending on country) an additional means of
disconnection must be provided for all poles of the power
supply. When switched off there must be an all pole contact
gap of 3 mm in the isolator switch. This 3 mm contact dis-
connect gap must apply to any isolator switch, fuses and/or
relays according to EN60335.
1 A
Electrical
Shock
Hazard
12 VDC
Plug power cord directly into a properly
grounded (earthed) outlet.
Do not defeat the grounding (earthing)
nature of the plug.
Do not use adapter or extension cord.
Failure to follow these instructions could
cause serious injury or death.
See installation instructions

Gas Supply

Installation must conform with local codes.
Locate the gas supply within the shaded area shown in the
illustrations on page 6.
The outdoor grill is equipped for use with natural or liquid
propane (LP) gas. The product rating plate has information
on the type of gas that should be used. For rating plate
location, refer to the illustration below. If this information
does not agree with the type of gas available, check with
the local gas supplier.
G A S RE Q U I R EMEN T S
N ATU R AL G AS
Supply Pressure
12.5 mbar
Min Line Pressure
17.5 mbar
Max Regulator Pressure
100 mbar
L P G AS
Supply Pressure
Min Line Pressure
27.4 mbar
Max Regulator Pressure
100 mbar
G A S R EQ U I R EMEN T S — FO R A U S T R AL I A O N LY
N ATU R AL G AS
Supply Pressure
Regulator Outlet
L P G AS
Supply Pressure
Grill Regulator Outlet
Side Burner Regulator Outlet
RATING PLATE
RATING PLATE
Outdoor gas grill.
Outdoor module.
WC
WC
25 mbar
k Pa
1.13
1.00
k Pa
2.75
2.60
2.70