Greenway GWD9500W-POU Guide D'utilisation Et D'entretien page 11

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Cleaning the Outside of the Water Dispenser:
The outside of the dispenser can be wiped clean with a Greenway
water mixture. Never use harsh chemicals or abrasive cleaners. Rinse thoroughly with clean water and then dry surfaces.
Cleaning the Condenser:
Vacuum or sweep away the dust from the condenser coils at the back of the dispenser. For best results, you can
purchase a brush designed specifically for this purpose from your local
appliance store. This will improve cooling and efficiency.
Internal Reservoir Water Overflow Protection:
The internal (cold tank) reservoir incorporates a water overflow flotation device.
(See Fig. 20)
"A" is the "primary" flotation device that manually controls incoming water and related water levels associated with
normal operating conditions. The design parameter of this device allows the
float to move freely "up/down" according to related water levels. As water levels
rise, so does the float causing the water inlet valve to close at a pre-determined
level. As water levels fall, so does the float causing the water inlet valve to open
allowing replenishment of water.
"B" is the "secondary" flotation device that engages "only" in the event of a
malfunction of flotation device "A" to prevent possible overflow conditions. The
design parameter of this device only allows the float to move "upward" as water
levels rise, causing the water inlet valve to close permanently. When flotation
device "B" engages, a manual "re-set" of the floatation device is required in order to restore normal (incoming) water
activity.
Re-Setting Water Overflow Protection:
1. Disconnect (unplug) the power cord.
2. Turn off the water supply, using manual shut-off valve at the rear of the dispenser.
3. Place cup/glass under dispensing spigot and drain approx. 3 cups of cold water.
4. Remove the top cover on the dispenser (See Fig. 17) by removing the two Philips screws located at the rear of the
cover (See Fig. 17A).
5. Carefully lift off the top cover.
6. Place a towel on top of the reservoir cover.
7. Push the white re-set button located on top of the reservoir cover (See Fig. 21).
A small burst of water will release from the re-set button depressurizing
the water line. This action will cause flotation device "B" to release. The
re- set procedure is now complete. Clean-up any access water on the
reservoir cover. Re-connect the power cord.
8. Slowly re-open the manual shut-off valve (at the rear of the dispenser). You
should hear water entering the reservoir. If not, close the manual shut-off
valve and repeat steps 1,2, 3, 6, 7, 8.
9. Re-install the dispenser top cover and secure using the two Philips screws.
10. Re-connect the power cord.
water dispenser cleaning solution or a mild soap and
®
9
Condenser
coils
B
A
Fig. 20
OVERFLOw RE-SET
Fig. 21
L
H

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Gwd9500bls-pou

Table des Matières