Télécharger Imprimer la page

EuroLite TMH-250 EHJ Moving-Head Mode D'emploi page 29

Publicité

Les langues disponibles

Les langues disponibles

The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.
OPERATION
After you connected the effect to the mains, the TMH-250 EHJ starts running. During the Reset, the motors
are trimmed and the device is ready for use afterwards.
Turn the focus-screw next to the objective-lens for adjusting the focus in order to obtain a sharp projection.
Display and function buttons
Press the Function Button and select from the functions F1 – F4.
F1 - Pan Reverse
With this function you can reverse the Pan-movement.
• Press the Function button and select „F2".
• Press the Up button to select "y" if you wish to enable this function or press the Down button to select "n"
if you don't.
F2 - Tilt Reverse
With this function you can reverse the Tilt-movement.
• Press the Function button and select „F2".
• Press the Up button to select "y" if you wish to enable this function or press the Down button to select "n"
if you don't.
F3 - 16 Bit operation
With this function you can reduce the projector-movement to 16 bit.
• Press the Function button and select „F3".
• Press the Up button to select "y" if you wish to enable this function or press the Down button to select "n"
if you don't.
F4 - Demo operation
In the Stand Alone mode, the TMH-250 EHJ can be used without controller. Disconnect the TMH-250 EHJ
from the controller and call up the internal program (F4).
• Press the Function button and select „F4".
• Press the Up button to select "y" if you wish to enable this function or press the Down button to select "n"
if you don't.
29/63