Télécharger Imprimer la page

Philips Lumea BRI944/00 Mode D'emploi page 25

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 81
Problem
The device produces a
strange smell.
The device does not flash,
the fan is not switched on
and all 5 intensity lights
blink.
The skin feels more
sensitive than usual
during treatment. I
experience discomfort
when I use the device.
There is no glass window
in my attachment.
Possible cause
The light exit window or
the SmartSkin sensor is
dirty.
You have not removed the
hairs on the area to be
treated properly. These
hairs may get burned and
can cause the smell.
The attachment is not
attached properly.
The light intensity setting
you use is too high.
You did not remove the
hairs on the areas to be
treated.
The UV filter of the light exit
window is broken.
You treated an area for
which the device is not
intended.
This is normal.
Solution
Clean the light exit window and the SmartSkin
sensor carefully.
Pretreat your skin before you use Lumea.
Make sure you attach the attachment
completely. If necessary, clean the electronic
contacts on the attachment.
Check if you have selected a comfortable light
intensity setting. If necessary, select a lower
setting.
Pretreat your skin before you use Lumea.
If the UV filter is broken, do not use the device
anymore. Contact the Consumer Care Center in
your country, your Philips dealer or a Philips
service center.
Never use the device on irritated (red or cut),
sunburned, recently tanned or fake-tanned skin.
Never use the device if you have infections,
eczema, burns, inflammation of hair follicles,
open lacerations, abrasions, herpes simplex (cold
sores), wounds or lesions and haematomas
(bruises) in the areas to be treated.
Never use the device on the following areas: on
moles, freckles, large veins, darker pigmented
areas, scars, skin anomalies without consulting
your doctor. Never use the device on warts,
tattoos or permanent make-up, around the eyes
and on or near the eyebrows, on the lips,
perineum, scalp, nipples, areolas, labia minora,
vagina, anus and the inside of the nostrils and
ears. Men must not use it on the face and neck
including all beard growing areas and whole
genital area. This can result in a burn and a
change in skin color, which makes it potentially
harder to identify skin-related diseases.
No action required: there is no glass window in
the body and underarm attachments. Only the
facial attachment has a red glass filter. The
precision and bikini attachments have a
transparent glass window.
English
25

Publicité

loading