Télécharger Imprimer la page

Teka DH2 ISLA 85 Serie Manuel D'instructions page 10

Masquer les pouces Voir aussi pour DH2 ISLA 85 Serie:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
Dear Customer,
Congratulations on your choice. We are certain that this
modern, functional and practical device made with first rate
quality materials will fully satisfy your requirements.
Please read all the sections in this INSTRUCTION MANUAL
before using the hood for the first time in order to obtain
maximum performance from the device and avoid faults
which may arise from incorrect use as well as minor problem
solving.
For optimal performance, the external duct should not exceed
FOUR METRES, have more than two 90 ° angles and its
diameter should be at least Ø120.
Safety Instructions
•Disconnect the device before
performing any work on the interior,
e.g. during cleaning or maintenance.
•The excessive accumulation of
grease in the hood and metal filters
may cause dripping and fire risks,
therefore it is necessary to wash
the inside of the hood and the metal
filters at least once a month.
•This device can be used by children
aged 8 and over and persons with
reduced physical, sensory or mental
capabilities or lack of experience and
knowledge, if they have been given
supervision or proper training in the
safe use of the device and if they
understand the dangers involved.
Children should not play with the
device. Cleaning and maintenance
should be performed by the user
and not by unsupervised children.
• The regulations for electrical
installations must be complied with.
•Check that the power voltage and
frequency match those indicated
on the label located on the inside
of the hood. A suitable earth must
be connected (except for Class II
devices, marked with
technical data plate).
•For installation, a connection
method isolated from the fixed
installation should be incorporated,
in accordance with installation
regulations (adjusted to the strength
to be endured and with a minimum
opening between the contacts of
3mm) under overvoltage category
III conditions, for the emergency
shutdown,
cleaning
replacement. In no event should the
earth pass through this switch. This
switch can be replaced with a plug if
it is accessible in normal use.
•If the power lead is damaged it must
be replaced by the manufacturer, its
after-sales service or by qualified
personnel in order to avoid potential
danger.
• Ventilation regulations must be
complied with.
• Air should not be extracted by ducts
used to expel fumes from equipment
powered by gas or other fuels.
on the
or
light

Publicité

loading

Ce manuel est également adapté pour:

Dh2 isla 1285