2 About the box
2
About the box
2.1
Outdoor unit
2.1.1
To remove the accessories from the
outdoor unit
e
a
b
f
c
ENERG
ENERG
Y
IJA
Y
IJA
IE
IA
IE
IA
g
d
h
a
Shut-off valve (with integrated filter)
b
O-ring for drain socket
c
Drain socket
d
Thermistor fixture (for installations in areas with low
ambient temperatures)
e
Installation manual – Outdoor unit
f
Disposal manual – Recovering refrigerant
g
Energy label
h
Discharge grille (upper + lower part)
i
Installation manual – Discharge grille
NOTICE
Unpacking – Front corners. When you remove the front
packaging corners, hold the box containing the discharge
grille to prevent it from falling.
3
Unit installation
3.1
Preparing the installation site
WARNING
The appliance shall be stored in a room without
continuously operating ignition sources (example: open
flames, an operating gas appliance or an operating electric
heater).
Installation manual
6
3.1.1
Installation site requirements of the
outdoor unit
Mind the spacing guidelines. See figure 1 on the inside of the front
cover.
Translation of text on figure 1:
English
General
No top-side obstacle
Top-side obstacle
Wall height unrestricted
The outdoor unit is designed for outdoor installation only, and for the
following ambient temperatures:
Cooling mode
Heating mode
Special requirements for R32
The outdoor unit contains an internal refrigerant circuit (R32), but
you do NOT have to do any refrigerant field piping, or refrigerant
charging.
Mind the following requirements and precautions:
WARNING
▪ Do NOT pierce or burn.
▪ Do NOT use means to accelerate the defrosting
process or to clean the equipment, other than those
i
recommended by the manufacturer.
▪ Be aware that R32 refrigerant does NOT contain an
odour.
WARNING
The appliance shall be stored so as to prevent mechanical
damage and in a well-ventilated room without continuously
operating ignition sources (example: open flames, an
operating gas appliance or an operating electric heater).
WARNING
Make sure installation, servicing, maintenance and repair
comply with instructions from Daikin and with applicable
legislation (for example national gas regulation) and are
executed only by authorised persons.
3.2
Mounting the outdoor unit
3.2.1
To provide the installation structure
NOTICE
Level. Make sure the unit is level. Recommended:
Translation
General
No top-side obstacle
Top-side obstacle
Wall height unrestricted
10~43°C
–28~35°C
EPRA14~18DAV3+W1
Daikin Altherma 3 H HT
4P586100-1C – 2020.01