1/ WARNING:
• The BOOSTER should always be used by skilled personnel.
• Warnings and instructions of the vehicle maker must be applied at all times.
• Wear protection goggles and equipment specified by regulations.
• Whenever left unused, the BOOSTER must be in charge.
• Always wind and store the cables properly to avoid any risk of contact between the clamps.
• Never produce short-circuits.
• Never use a 24 Volt BOOSTER on a 12 Volt vehicle.
• Never use a 12 Volt BOOSTER on a 24 Volt vehicle.
• After-sales interventions must be performed only by FACOM After-sales.
2/ SPECIFICATIONS :
Usage voltage
Max Peak current
Cranking current
TCFC current*
Battery capacity
Battery type
Battery reference
Cable Ø
Cable type
Cable length
Clips
Weight
Fuse type
Power fuse
Fuse reference
Voltage selection
Safeties
Charger type
INPUT charger
OUTPUT charger
EU charger reference
UK charger reference
booster NU-B124.1A_0417.indd 5
B124.1A
12V -24V
3700A
1400A
1000A
2 X 20 Ah
AGM
B124.1A-BAT
35mm²
Double insulation copper
155 cm
850 A Bronze
20,7 KG
MEGA
300A
BF300A
By 4-terminal
power connector
Buzzer if polarity reversal, fuse
Automatique 4A
220 - 240V 50/60 hz
DC 12V 4A
B124-CH4
Non disponible
EN
5