Dual access opening (4 eyes mode)
3.4 Dual access opening mode (4 eyes mode)
In this mode, two different codes have to be dialled to release the opening of the lock.
3.4.1 Activating the dual access opening mode (4 eyes mode)
C
Type in the master code +
C
When the green light is displayed, open the door.
C
Door opened, type in master code again +
C
Type "12" +
C
Type "1" +
The function is activated.
Even if the dual access mode is activated, the master code or the C.I.T code
alone allows the unlocking of the door.
When in dual access mode, the delay applied before opening is the one of
the second code dialled.