Installation Module w/ CK 31
Type
Polar pattern
Frequency range
Sensitivity
Electrical impedance
Rated load impedance >2000 Ω
Power requirement
Size (dia. x length)
Connector**
Installation Module w/ CK 47
Type
Polar pattern
Frequency range
Sensitivity
Electrical impedance
Rated load impedance >2000 Ω
Power requirement
Size (dia. x length)
Connector**
* Re 1 V/Pa
** Except GN 30 OC and LM 3 L
This product conforms to the EN 540082-1 standard provided it is connected to
audio/power supply equipment with the CE mark.
Pre-polarized condenser microphone
Cardioid
50-20,000 Hz
20 mV/Pa
-34 dBV*
<600 Ω
9-52 V phantom power to DIN 45596 -
Requires DPA adapter (integrated in GN**,
LM 3, and HM 1000 Installation Modules)
13 x 25 mm
(0.5 x 0.95 in.)
XLR-3
Pre-polarized condenser microphone
Hypercardioid
20-20,000 Hz
16.5 mV/Pa
-35.5 dBV*
<600 Ω
9-52 V phantom power to DIN 45596 -
Requires DPA adapter (integrated in GN**,
LM 3, and HM 1000 Installation Modules)
13 x 154 mm
(0.5 x 5.85 in.)
XLR-3
5 Specifications
CK 32
Omni
20-20,000 Hz
14 mV/Pa
-37 dBV*
<600 Ω
>2000 Ω
13 x 25 mm
(0.5 x 0.95 in.) (0.5. x 0.95 in.)
XLR-3
CK 80
Hypercardioid
60-15,000 Hz
30 mV/Pa
-30 dBV*
<600 Ω
>2000 Ω
13 x 128 mm
(0.5 x 4.86 in.)
XLR-3
CK 33
Hypercardioid
50-20,000 Hz
20 mV/Pa
-34 dBV*
<600 Ω
>2000 Ω
13 x 25 mm
XLR-3