Télécharger Imprimer la page

Italiana Camini IDRO 30 Installation, Usage Et Maintenance page 23

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 28
SYSTEM FOR AN OPEN/CLOSED TANK INSTALLATION
AN EXAMPLE OF A HYDRAULIC SYSTEM FOR A THERMO FIREPLACE THAT PRODUCES AND STORES HOT SANITARY WATER AND HAS A WALL MOUNTED BOILER
TM
IDROKIT is designed to facilitate the work carried out by the installers. In fact, it consists of all the necessary components for the product
to be properly installed.
1
3
6
8
cm 44
cm 45
IDROKIT
10
2
4
5
9
7
11
A
B
D
E
F
ACS:
Hot Sanitary Water
AF:
Cold Water
AL:
Water Mains Supply
C:
Filling/Top-Up Section
CE:
Electronic Panel
EV:
3-way Solenoid Valve
NA:
Normally Open
NC:
Normally Closed
GR:
Pressure Reducer
Ja:
Automatic Relief Valve
Jm:
Manual Relief Valve
MI:
System Flow
MT:
Thermostatic Mixer
P:
Pump (circulator)
RA:
Radiators
RI:
System Return
S:
Drain
SC30:
30-plate Heat Exchanger
ST:
Temperature Sensor
TC:
Contact Thermostat
TM:
Thermo Fireplace
V:
Ball Valve
Vea:
Open Expansion Tank
Vec:
Closed Expansion Tank
VR:
Check Valve
VSPT:
Safety Pressure and Temperature Valve
VCA:
Boiler
1
heating return
2
gas boiler hot sanitary water
3
thermo fireplace flow
4
drain
5
hot sanitary water
6
thermo fireplace return
7
heating flow
8
water mains
9
thermostatic mixer setting
10
synoptic panel
11
auxiliary socket for a room thermostat
A 30-plate Heat Exchanger
B primary circulator (in the wood-fired version)
C 50-litre boiler
D heating system circulator
E closed expansion tank
C
F fireplace covering for exposed installation
IDROKIT
IDROKIT
USING
code 601740
23

Publicité

loading

Ce manuel est également adapté pour:

Idro 30 cs