Settings (con't)
Humidification
68
80
80
Enable Humidification?
No
Resume Schedule
Away
75
71
75
Humidify Set Point
30 %
Humidify During...
Heat
Smart Control
Off
Away
Home
Humidity With Fan
Off
72
65
OFF
BACK
How to test a humidifier
Adjust the humidify set point up to 'TEST', select Humidify during "Heat/Fan", then turn on a continuous fan speed on
the Fan screen under Settings. This should force the humidifier to run. This setting will last for 30 minutes, where the
maximum setting will return to 4% below the dehumidification set point.
Settings
80
80
68
Resume Schedule
Away
71
75
75
Basic
Time
Humidity
Home
Away
Away
Vacation
Fan
72
65
OFF
BACK
68
Away
71
OFF
> Return to Table of Contents
Smart Control – Smart Control is used to reduce or prevent water condensation
Zone 3
on the inside of windows while humidifying in the winter season. The control
monitors indoor and outdoor temperatures and reduces the humidification
percentage according to the Smart Control level chosen by the user. Start out with
44%
44%
47%
the Low setting. If objectionable condensation occurs on windows, choose the
Medium or High setting.
Dining Room
Humidify With Fan – If there is a call to humidify and the fan and heating/
cooling are off, the fan will be forced on to humidify. Select the desired fan speed
from Low to High.
Note: Humidification is only available if a humidifier is installed.
Away Settings (Menu > Settings > Away)
Zone 3
Your system will follow the customized heating, cooling and fan settings when
you place your system into 'Away' mode. The system can be placed into Away
47%
44%
44%
by selecting the Home icon (closed door) on the home screen. Once the system is
placed into Away mode it will remain until canceled. Simply tap the Away icon
(open door) to exit Away mode. The system will resume the schedule or return to
Installer
Dining Room
the previous settings if a schedule is not being followed. You can also exit Away
by increasing or decreasing the temperature.
Note: If your system is in Cool or Heat when placed into Away mode your system will only manage to
the respective Away set point.
If you have an EcoNet Zoning System and the EcoNet Zone Control 'Away'
Zone 3
heat set point is set to 50°F (10°C) or the cool set point is set to 92°F (33°C), the
Zone Control will default to Off. Adjusting the 'Away' heat set point as low as
51°F (11°C) and the cool set point up to 91°F (32°C) will allow the zone to be
47%
conditioned when required.
Configure individual 'Away' settings for each zone from the EcoNet Zone Control or
Dining Room
through the EcoNet App. From the respective Zone Control unit, tap Menu > Away
to configure the unique 'Away' set point for a particular zone.
Refer to pg.17 to enable your Zoning System.
EcoNet
Smart Thermostat User Guide
®
15