Settings (con't)
Basic Settings
80
68
80
Set Point Deadband
2º F
Resume Schedule
Away
71
75
75
Temperature Offset
0.0º F
Relative Humidity Offset
0.0 %
Room Sensor Selection
Internal
Away
Home
Proximity Sensing?
Yes
Smooth Arrival Enabled?
Yes
72
65
OFF
BACK
Basic Settings
80
68
80
Backlight Enabled?
Yes
Resume Schedule
Away
71
75
75
Away
Home
72
65
OFF
BACK

Settings

80
68
80
Resume Schedule
Away
71
75
75
Basic
Time
Humidity
Home
Away
Away
Vacation
Fan
65
72
OFF
BACK
Time and Date
68
80
80
Resume Schedule
Away
71
75
75
2
:
38
pm
Settings (con't)
Home
Away
Jan
29
2018
Settings (con't)
72
65
Accept
D.S.T.
OFF
BACK
> Return to Table of Contents
More >
Zone 3
Set Point Deadband – This is the minimum difference between heating and
cooling set points in Auto mode. The default is 2 degrees. This setting is
configurable between 0 and 6 degrees. A 0 degree deadband means your system
44%
44%
47%
will switch between heating and cooling to maintain the specified set point. The
smaller the deadband setting the more frequently your system will switch between
Dining Room
MORE
heating and cooling.
Temperature Offset – This is an offset applied to the displayed room
temperature. A negative offset will cause the displayed indoor temperature to
be less than the sensed temperature. A positive offset will cause the displayed
temperature to be higher than sensed temperature.
Relative Humidity Offset – This is an offset applied to the indoor relative
humidity. A negative offset will cause the displayed relative humidity to be less
than the sensed relative humidity. A positive offset will cause the displayed relative
humidity to be higher than sensed relative humidity.
Note: You should allow the thermostat to calibrate in the conditioned space for 30 minutes before
adjusting offsets.
Room Sensor Selection – You can wire a remote 10K temperature sensor*
to the EcoNet Smart Thermostat. If a remote temperature sensor is connected, you
can choose to use the remote sensor, internal sensor on the Smart Thermostat or an
average between the two for current indoor temperature.
*Optimized for use with an Aprilaire 8051 indoor temperature sensor.
Proximity Sensing – Selecting 'No' will disable the motion sensor. To activate
the thermostat, you will need to tap the screen.
Smooth Arrival – The thermostat will intelligently start the system early in order
to reach the desired temperature set point at the scheduled time, while using the
least amount of energy.
Backlight Enabled – When the thermostat is not being used it will enter
Zone 3
standby mode. The default screen brightness in standby is 1%. You can turn off the
Backlight when in standby by selecting "No."
47%
44%
44%
Dining Room
Time & Date (Menu > Settings > Time)
Zone 3
Set the current time and date. Your schedule times, vacation events and weather
forecast will be based off the time entered on this screen. It is important to ensure
the correct date and time are programmed before
44%
47%
44%
setting your schedule.
Dining Room
Installer
DST – At the bottom of this screen you can elect to enable or disable
Zone 3
daylight savings time.
44%
47%
44%
Yes