Connect
Electrical
Supply
• ,
WARNING
RISK OF ELECTRIC SHOCK
Before wiring the appliance,
interrupt the main
electrical circuit at the electrical control cabinet. A
circuit with 120 VAC, 15 or 20 Ampere is required.
Grounding notes: this appliance
is equipped with a
distributor
box with 3 cables. Use the green-yellow
cable for grounding
the appliance.
Connect the
green-yellow cable to the grounding cable on the
house connection
to prevent electric sthock. Do not
under any circumstances
damage or remove the
green-yellow cable. Non-adherence
can cause
deadly injuries or electric shock.
Attaching
flue duct
Hidden surfaces may have sharp edges. Use caution
when reaching behind or under appliance.
1. Remove the protective foil from both flue ducts.
2. Push one flue duct into the other.
Notes
o To prevent scratches, lay paper over the edges of
the lower flue duct to protect the surface.
o For ducted operation, turn the upper flue duct so
that the ventilation slots point downward.
1. Remove the left cable passage and the cover of the
motor controller.
Fasten the connecting
piece for the
installation pipe (listed in cULUS) to the cable
passage.
B
/
A
Cable passage
B
Cover of the motor controller
2. Connect
1/2' (12.7 mm)installation
pipe to motor
controller.
A
......
r.........
A
Installation pipe
B
Power connection
C
Cable connector
listed in UL
3. Remove the protective foil from the extractor hood.
4. Place flue ducts on the appliance.
5. Push the inner flue duct upwards and attach it to the
angle brackets on the left and right.
6. Screw the flue duct to the sides of the angle bracket
using two screws.
A
Upper flue duct
B
Lower flue duct
C
Screws
D
Angle bracket
12