Pince à sertir pneumatique

Publicité

Les langues disponibles

Les langues disponibles

The AC 100 must be opened.
Disconnect compressed air!
Cleaning
 Unscrew hexagon socket screw (1).
 Pull out die set (2).
 Clean die set (3) and lightly oil pivot (4).
 Push in die set (5).
 Tighten hexagon socket screw (6).
Lubrication
 Unscrew the head (1).
 Remove the spring (2) and piston (3).
 Lubricate the two arms of the die set (4)
(e. g. Gleitmo 746).
 Insert piston and spring.
 Insert head (5) and fasten fingertight.
 Pay attention that the arms of the die set
(4) are correctly engaged in the piston (3).