Télécharger Imprimer la page

Kohler K-1122 Guide D'installation page 7

Masquer les pouces Voir aussi pour K-1122:

Publicité

Les langues disponibles

Les langues disponibles

Bond in accordance
with applicable codes.
Heater
6. Make Electrical Connections
WARNING: Risk of electric shock. Make sure the power has been disconnected before performing
the following procedures.
WARNING: Risk of electric shock. To reduce the risk of electrical shock, connect the pump and
in-line heater (if heater option included) to properly grounded, grounding-type receptacles
protected by Ground-Fault Circuit-Interrupters (GFCI's). Do not remove the plugs' grounding pins.
Do not use grounding adapters.
Pump Wiring
NOTE: The whirlpool model number is printed on a label near the whirlpool pump. This label also
identifies the electrical rating of the whirlpool.
Your Kohler whirlpool bath is equipped with a cord and plug. All wiring of the pump and control
has been completed at the factory. A licensed electrician must install a GFCI-protected, 120 V, 15 A,
grounded outlet. No other load should be on this circuit. Locate the outlet behind the whirlpool,
and within 24" (61 cm) of the pump.
Plug the pump into this outlet.
NOTE: Make sure the air actuator tubing is securely attached to the pump, and is not kinked or damaged.
If a K-1639 Timer Kit will be used, install it now according to the instructions packed.
In-line Heater Wiring
"H" Models: The heater is equipped with a cord and plug. All wiring of the heater has been
completed at the factory. A licensed electrician must install a GFCI-protected, 120 V, 15 A, grounded
outlet. No other load should be on this circuit. Locate the outlet behind the whirlpool, and within
24" (61 cm) of the heater.
Plug the heater into this outlet.
7. Test Run the Whirlpool
Check all electrical connections, and make sure the electrical power to the whirlpool and heater (if
equipped) is on.
Make sure all union connections to the pump and heater are securely hand tightened.
Verify that the pump banding straps have been cut (if applicable), and that the pump is resting
directly on the subfloor or whirlpool base.
Fill the whirlpool to a level at least 2" (5.1 cm) above the top of the highest jet.
Kohler Co.
All manuals and user guides at all-guides.com
7
Plug the pump
into this outlet.
Install second GFCI-
protected outlet for "H"
models for the in-line heater.
Install a GFCI-
protected 120 V, 15 A
grounded outlet.
1010997-2-E