WIKA FSD-4 Mode D'emploi page 30

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

9. Specifications
Further details on: Output signal
Analogue output
EN
IO-Link
Switching function
Contact function
Setting range of the switch points
Flow
Temperature
Load in Ω
Analogue signal 4 ... 20 mA
Analogue signal DC 0 ... 10 V
Signal clamping
Switching current
1)
Switching voltage
Communication
Communication protocol
30
Flow, 4 ... 20 mA
Flow, 0 ... 10 V
Temperature, 4 ... 20 mA
Temperature, 0 ... 10 V
Factory setting: Flow, 4 ... 20 mA
IO-Link is optionally available for all output signal configurations
Hysteresis
Window
Factory setting: Hysteresis
Normally open
Normally closed
Factory setting: Normally open
0.05 ... 3 m/s [0.16 ... 9.84 ft/s]
Factory setting: 3 m/s
-18.2 ... +85 °C [-0.8 ... +185 °F]
Factory setting: 85 °C
≤ 500 Ω
> max. output voltage/1 mA
I
= 3.8 mA
min
I
= 20.5 mA
max
U
= 0 V
min
U
= 10.3 V
max
Max. 250 mA per switching output
Supply voltage - 1 V
IO-Link 1.1
2)
WIKA operating instructions flow switch, model FSD-4

Publicité

Table des Matières
loading

Table des Matières