General Description
This airless sprayer is a precision power tool used for spraying
many types of materials. Read and follow this instruction manual
carefully for proper operating instructions, maintenance, and safety
information.
Motor
Filter
assembly
PRIME /
SPRAY Valve
Outlet
tting
Operation
This equipment produces a fluid stream at extremely
high pressure. read and understand the warnings
in the Safety Precautions section at the front of this
manual before operating this equipment.
English
Setup
Perform the following procedure before plugging in the power cord
of an electric unit.
1. Ensure that the siphon tube and the return hose are attached
and secure.
2. Using a wrench, attach a minimum of 50' of 1/4" airless spray
hose to the outlet fitting on the sprayer. Tighten securely.
3. Attach an airless spray gun to the spray hose. Using two
wrenches (one on the gun and one on the hose), tighten
securely.
Pressure
control knob
NOTE: Do not attach the tip to the spray gun yet. remove
(reverse side)
Digi-Trac™ Screen
(reverse side)
Oiler Cap
4. Make sure the pressure control knob is in its OFF position in
Oiler button
the black zone.
Fluid section
5. Make sure the ON/OFF switch is in its OFF position.
6. Remove the fill cap with a straight-slot screwdriver, or a coin.
Fill the oil reservoir with one ounce of piston seal lubricant
Siphon tube
(Piston Lube). Replace oiler cap.
Return tube
7. Press oiler button 2-5 times to prime the oiler. Press once for
every eight hours of usage to lubricate the fluid section.
ImPOrTaNT: Never operate unit for more than ten seconds
without fluid. Operating this unit without fluid will cause
unnecessary wear to the packings.
8. Make sure the electrical service is 120V, 15 amp minimum.
9. Plug the power cord into a properly grounded outlet at least
25' from the spray area.
ImPOrTaNT: always use a minimum 12 gauge, three-wire
extension cord with a grounded plug. Never remove the third
prong or use an adapter.
Preparing a New Sprayer
If this sprayer is new, it is shipped with test fluid in the fluid section to
prevent corrosion during shipment and storage. This fluid must be
thoroughly cleaned out of the system with mineral spirits before you
begin spraying.
ImPOrTaNT: always keep the trigger lock on the spray gun in
the locked position while preparing the system.
1. Place the siphon tube into a container of mineral spirits.
2. Place the return hose into a metal waste container.
3. Set the pressure to minimum by turning the pressure control
knob to the "MIN" setting.
Pump OFF
4. Move the PRIME/SPRAY valve down to the PRIME position.
5. Turn on the sprayer by moving the ON/OFF switch to the ON
position.
6. Allow the sprayer to run for 15–30 seconds to flush the
test fluid out through the return hose and into the waste
container.
7. Turn off the sprayer by moving the ON/OFF switch to the OFF
position.
4
the tip if it is already attached.
make sure all airless hoses and spray guns are
electrically grounded and rated at or above the
maximum operating pressure range of the airless
sprayer.
RAPID
CLEAN
RapidClean
Pressure
Indicator
Pressure
Control Knob